2014
DOI: 10.1167/iovs.13-13813
|View full text |Cite
|
Sign up to set email alerts
|

Reducing Variability in Visual Field Assessment for Glaucoma Through Filtering That Combines Structural and Functional Information

Abstract: PURPOSE. To reduce variability and improve measurements of true change signal in visual field (VF) assessments through the use of filters that combine functional and structural test results.METHODS. Humphrey VF data (Swedish Interactive Thresholding Algorithm [SITA] Standard, 24-2) and confocal scanning laser ophthalmoscopy (Heidelberg Retina Tomograph [HRT]) data from 1057 eyes of 637 participants were used to derive a filter. Another dataset, consisting of VF and HRT data from 112 eyes of 62 participants eac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 45 publications
0
2
0
Order By: Relevance
“…For example, variability in SAP data can be reduced through improved data acquisition methods. 7 Alternatively, post-processing techniques, such as spatial filtering of currently available data 8 11 appear to reduce variability or choosing a more valid statistical model, 12 explains variability in the SAP data to some degree. Furthermore, a recent study 13 recommended using Goldmann size V stimuli instead of size III to produce more reliable VF data later into the glaucomatous disease process.…”
Section: Introductionmentioning
confidence: 99%
“…For example, variability in SAP data can be reduced through improved data acquisition methods. 7 Alternatively, post-processing techniques, such as spatial filtering of currently available data 8 11 appear to reduce variability or choosing a more valid statistical model, 12 explains variability in the SAP data to some degree. Furthermore, a recent study 13 recommended using Goldmann size V stimuli instead of size III to produce more reliable VF data later into the glaucomatous disease process.…”
Section: Introductionmentioning
confidence: 99%
“…Variables associated with VF loss and VF variability may help identify patients who need greater clinical scrutiny. Variability obscures the identification of true glaucomatous progression in VF and makes detection of progression challenging [37]. Therefore, reducing variability is particularly important [30] as the change in a glaucomatous VF must be greater than the noise about the measurement before it becomes statistically distinguishable [25, 28].…”
Section: Discussionmentioning
confidence: 99%