2019
DOI: 10.1111/aor.13477
|View full text |Cite
|
Sign up to set email alerts
|

Reducing regional flow stasis and improving intraventricular hemodynamics with a tipless inflow cannula design: An in vitro flow visualization study using the EVAHEART LVAD

Abstract: Due to the high stroke rate of left ventricular assist device (LVAD) patients, reduction of thrombus has emerged as an important target for LVAD support. Left ventricular blood flow patterns with areas of flow stasis and recirculation are associated with platelet aggregation, which is worsened by exposure to high shear stress. Previous reports of intraventricular thrombus in LVAD patients have identified the outside of the LVAD inflow cannula as a nidus for LV thrombus formation. Previous studies of LVAD inflo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(21 citation statements)
references
References 55 publications
0
21
0
Order By: Relevance
“…Karen May‐Newman et al of San Diego State University, San Diego, CA, USA investigated in vitro a “tipless” inflow cannula for the EVAHEART LVAS to reduce regional flow stasis and improving intraventricular hemodynamics. The cannula was inserted flush with the endocardial border and did not protrude into the left ventricle (LV) and compared to the standard cannula position with a 1‐cm insertion into the LV.…”
Section: Cardiac Support and Blood Pumpsmentioning
confidence: 99%
“…Karen May‐Newman et al of San Diego State University, San Diego, CA, USA investigated in vitro a “tipless” inflow cannula for the EVAHEART LVAS to reduce regional flow stasis and improving intraventricular hemodynamics. The cannula was inserted flush with the endocardial border and did not protrude into the left ventricle (LV) and compared to the standard cannula position with a 1‐cm insertion into the LV.…”
Section: Cardiac Support and Blood Pumpsmentioning
confidence: 99%
“…In fact, it is known that adaptation to flows in the presence or absence of the cannula determines favorable conditions to the thrombi’s formation, even after the explant has taken place 18 . Furthermore, many other factors such as cannula material and surface characteristics, as well as the patients' coagulation status may be of some clinical significance, explaining the differences observed in the flow field 19 …”
Section: Restoration Of Left Ventricular Performancementioning
confidence: 99%
“…18 Furthermore, many other factors such as cannula material and surface characteristics, as well as the patients' coagulation status may be of some clinical significance, explaining the differences observed in the flow field. 19 We believe that, once the stabilization and well-being of patients have been achieved, major efforts should be made to progressively and slowly reduce LVAD pump flow, allowing the restoration of left ventricular performance. In our opinion, this approach is the only one that could in principle drive to left ventricular function recovery.…”
Section: Introductionmentioning
confidence: 99%
“…EVAHEART (EVAHEART, Inc., Houston, TX) cannula 15,16 postulated that systematic washout may reduce the risk of thrombosis. However, these experimental studies were performed in inert replicas of the left ventricle, with a blood analog, and therefore, did not explicitly consider the surface properties, nor coagulation factors.…”
Section: Introductionmentioning
confidence: 99%