2020
DOI: 10.1007/s10840-020-00737-7
|View full text |Cite
|
Sign up to set email alerts
|

Reducing radiation exposure in second-generation cryoballoon ablation without compromising clinical outcome

Abstract: Purpose Pulmonary vein isolation (PVI) using cryoballoon (CB) ablation is associated with an increased radiation exposure compared with radiofrequency ablation. Previous studies showed that radiation exposure in CB PVI can be reduced by optimizing the fluoroscopy protocol without comprising acute efficacy and safety. We evaluated the mid-term outcome of a modified fluoroscopy protocol in patients undergoing CB PVI. Methods The study population comprised 90 consecutive patients who underwent second-generation C… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 20 publications
(39 reference statements)
2
3
0
Order By: Relevance
“…In other studies, mid‐term follow‐up data after CB2 PVI showed freedom from AF between 64% and 84%, depending on follow‐up intensity and patient characteristics undergoing PVI 15–19 . Our data are in good accordance with follow‐up data after CB2 PVI presented by Holl et al 8 . The authors also used a modified radiation protocol and found that a reduced radiation exposure did not compromise freedom from AF after a mid‐term follow‐up.…”
Section: Discussionsupporting
confidence: 90%
See 2 more Smart Citations
“…In other studies, mid‐term follow‐up data after CB2 PVI showed freedom from AF between 64% and 84%, depending on follow‐up intensity and patient characteristics undergoing PVI 15–19 . Our data are in good accordance with follow‐up data after CB2 PVI presented by Holl et al 8 . The authors also used a modified radiation protocol and found that a reduced radiation exposure did not compromise freedom from AF after a mid‐term follow‐up.…”
Section: Discussionsupporting
confidence: 90%
“…On the other hand, when compared with conventional RF ablation, CB PVI is associated with a prolonged fluoroscopy time/higher radiation exposure, since CB PVI is fluoroscopy guided while RF‐ablation is typically supported by 3D electroanatomical mapping 3–6 . Modifications of radiation modalities by reducing fluoroscopy frame rates, optimizing collimation, omitting cine runs together with selective PV angiographies, and preferring fluoroscopic pa projections, whenever possible can significantly reduce radiation exposure, as shown in our study and demonstrated by others recently 8–10 …”
Section: Discussionsupporting
confidence: 67%
See 1 more Smart Citation
“…Non-fluoroscopic ablation reduced the use of X-rays without compromising the duration, effectiveness, and safety of the procedure. Also, although CBA requires more extensive radiation guidance than RFCA, ways to reduce radiation exposure are being explored in CBA as well [26].…”
Section: Discussionmentioning
confidence: 99%
“…Over the years, the approach to PVI with a cryoballoon has undergone refinements and modifications to optimize the procedural workflow [5]. These measures include the following: singlefreeze strategy (eliminating a bonus freeze), shorter freezing application (180 versus 240 s), time-to-isolation (TTI)guided ablation, shorter distal tip, radiation reduction, and the use of a figure-of-8 suture [6][7][8][9][10][11][12].…”
Section: Introductionmentioning
confidence: 99%