2019 IEEE Power &Amp; Energy Society General Meeting (PESGM) 2019
DOI: 10.1109/pesgm40551.2019.8973798
|View full text |Cite
|
Sign up to set email alerts
|

Reducing Peak Current and Energy Dissipation in Hybrid HVDC CBs Using Disconnector Voltage Control

Abstract: Peak fault current and energy dissipation in high voltage direct current (HVDC) circuit breakers (CBs) are very important parameters that impact dc grid protection development. This paper analyses a hybrid DCCB (HCB) control that reduces peak current and energy dissipation, by regulating the voltage across contacts of the ultra-fast disconnector (UFD). This is achieved by manipulating the number of inserted surge arresters while contacts of the UFD are moving apart. The controller is seamlessly integrated with… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
23
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 10 publications
(24 citation statements)
references
References 3 publications
1
23
0
Order By: Relevance
“…5 shows the experimental LC DC CB. The high-speed disconnector operates in around 2 ms with 3 mm separation in air, and it is described in [17,22]. Copper contacts of 20 mm width are used, while the closed-state overlap is OL = 1.5 mm.…”
Section: Experimental Circuitmentioning
confidence: 99%
See 1 more Smart Citation
“…5 shows the experimental LC DC CB. The high-speed disconnector operates in around 2 ms with 3 mm separation in air, and it is described in [17,22]. Copper contacts of 20 mm width are used, while the closed-state overlap is OL = 1.5 mm.…”
Section: Experimental Circuitmentioning
confidence: 99%
“…The experimental LC DC CB is using the same test system, same disconnector and control as the reported hybrid DC CB [22], to enable comparison. However in [22] the current peaks at much 6 Evaluation of 320 kV series LC DC CB…”
Section: Testing DC Fault Current Interruptionmentioning
confidence: 99%
“…Although [24] proposed a new type of HCB based on a disconnector voltage control technique that can reduce peak current as well as energy wastage. And [25] proposed a LVDC HBD topology that was shown to dissipate less energy.…”
Section: A Problem Statementmentioning
confidence: 99%
“…Experimental verification of topology 2 has been carried out using 900 V, 500 A DC CB test circuit and HCB prototype, described in [18]. The main breaker parameters are given in Table III in the appendix.…”
Section: Laboratory Hardware Demonstrationmentioning
confidence: 99%