2016
DOI: 10.1016/j.nima.2016.04.010
|View full text |Cite
|
Sign up to set email alerts
|

Reduced γ–γ time walk to below 50 ps using the multiplexed-start and multiplexed-stop fast-timing technique with LaBr3(Ce) detectors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
23
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 41 publications
(23 citation statements)
references
References 21 publications
0
23
0
Order By: Relevance
“…This procedure generates two independent fast-timing-array time spectra depending on whether the decay transition of the γ feeder -γ decay cascade provided a stop signal (the delayed time spectrum) or a start signal (antidelayed) as described in more detail in Refs. [16][17][18]. According to the generalized centroid difference (GCD) method and assuming no background contributions, the measurement of the relative time shift between the centroids (first moment of a time distribution) of the delayed and the antidelayed time spectra of a γ -γ cascade provides the centroid difference and corresponds to [17]:…”
Section: Experimental Setup Methods and Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…This procedure generates two independent fast-timing-array time spectra depending on whether the decay transition of the γ feeder -γ decay cascade provided a stop signal (the delayed time spectrum) or a start signal (antidelayed) as described in more detail in Refs. [16][17][18]. According to the generalized centroid difference (GCD) method and assuming no background contributions, the measurement of the relative time shift between the centroids (first moment of a time distribution) of the delayed and the antidelayed time spectra of a γ -γ cascade provides the centroid difference and corresponds to [17]:…”
Section: Experimental Setup Methods and Resultsmentioning
confidence: 99%
“…The mirror symmetry provides additional PRD data, e.g., PRD feeder (E feeder ) = 0, for a precise determination of the PRD(E γ ) curve [18]. Using a standard 152 Eu source and the neutron-capture reaction 48 Ti(n,γ ) 49 Ti, the PRD curve of the fast-timing array including the electronics setup has been determined for the energy region of 0.04-6.8 MeV [16].…”
Section: Experimental Setup Methods and Resultsmentioning
confidence: 99%
“…[31] to determine the g factors proved to be incorrect. With the new values of τ 2 + determined in this work, the following g factors are obtained: g( 140 Xe; 2 + ) = 0.56 (19) and g( 142 Xe; 2 + ) = 0.49 (9). These values are currently not reproduced by theory calculations (see Refs.…”
Section: Comparison With Theorymentioning
confidence: 88%
“…A detailed description of the PRD calibration procedure is given in Ref. [19]. The derived prompt response differences were fitted with the function:…”
Section: Determination Of the Lifetimes-the Generalized Centroidmentioning
confidence: 99%
See 1 more Smart Citation