2014 IEEE Energy Conversion Congress and Exposition (ECCE) 2014
DOI: 10.1109/ecce.2014.6953595
|View full text |Cite
|
Sign up to set email alerts
|

Reduced cost of reactive power in doubly fed induction generator wind turbine system with optimized grid filter

Abstract: The modern grid requirement has caused that the wind power system behaves more like conventional rotating generators and it is able to support certain amount of the reactive power. For a typical doubly-fed induction generator wind turbine system, the reactive power can be supported either through the rotor-side converter or the grid-side converter. This paper firstly compares the current ripples and supportive reactive power ranges between the conventional L and optimized LCL filter, if the reactive power is i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
27
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 13 publications
(27 citation statements)
references
References 22 publications
0
27
0
Order By: Relevance
“…the studies by Petersson, Zhang and Zhou. [24][25][26] The fact that their results have been largely ignored by the papers written from system perspective supports the idea that for system analyses, WP models with lower modelling detail would be helpful.…”
Section: Literature Analysismentioning
confidence: 90%
See 1 more Smart Citation
“…the studies by Petersson, Zhang and Zhou. [24][25][26] The fact that their results have been largely ignored by the papers written from system perspective supports the idea that for system analyses, WP models with lower modelling detail would be helpful.…”
Section: Literature Analysismentioning
confidence: 90%
“…For most WPs, the actual utilization of CQ will vary throughout the day. The analyses of Zhou et al 26 were carried out on generator level. In Zhang et al, 15 the reactive power range between˙0.3 pu is analyzed for one wind speed, likewise the analysis in Zhang et al 16 focuses on the analysis of different reactive power operating points in the same range at one wind speed, complemented by an analysis of losses at different wind speeds for one reactive power operating point.…”
Section: Literature Analysismentioning
confidence: 99%
“…The impedance model of the RSC and DFIG is shown in Figure 4. The slip angular speed can be expressed as (7) by transforming the rotor current control from the synchronous reference frame into rotor stationary reference.…”
Section: Impedance Modelingmentioning
confidence: 99%
“…Many researchers have investigated the degradation of the electrolytic capacitors [5]- [8]. For instance, a real-time failure detection is developed for the changes of the ESR and capacitance of the capacitors [6].…”
Section: Introductionmentioning
confidence: 99%
“…Lifetime prediction models of electrolytic capacitors are established for the switch-mode power supplies and variablefrequency drivers [7]. However, few studies investigate the degradation effect on reliability evaluation considering the mission profile [8], and this paper develops the approach to evaluate the reliability of power capacitors used in power conversion stage. Moreover, it is a physics-of-failure approach from the component-level [9] to system-level reliability that integrates the electrical modeling, thermal modeling, Weibull distribution, and reliability block diagram.…”
Section: Introductionmentioning