Abstract: Abstract.Information from theoretical models of redox enzyme linked biosensors highlights the importance of membrane thickness and enzyme loading on signal response in regard to both sensitivity and reproducibility. The conclusions are substantiated by examination of practical examples in the literature and, with a view to the importance of the character of the enzyme layer and overlayers, immobilization techniques are assessed which are in current use.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
52
0

Year Published

1998
1998
2004
2004

Publication Types

Select...
7

Relationship

5
2

Authors

Journals

citations
Cited by 60 publications
(55 citation statements)
references
References 103 publications
(73 reference statements)
3
52
0
Order By: Relevance
“…The insensitivity in dynamic range to the enzyme loading is in contrast to thick film enzyme electrodes where an increase in catalytic activity is shown to provide an increase in sensitivity but at the cost of a reduced dynamic range. 35,57 Increasing mediator concentration has an even more dramatic and positive effect on the response of the SAM enzyme electrodes (Fig. 6).…”
Section: Tuning the Response Of The Enzyme Electrodementioning
confidence: 99%
See 3 more Smart Citations
“…The insensitivity in dynamic range to the enzyme loading is in contrast to thick film enzyme electrodes where an increase in catalytic activity is shown to provide an increase in sensitivity but at the cost of a reduced dynamic range. 35,57 Increasing mediator concentration has an even more dramatic and positive effect on the response of the SAM enzyme electrodes (Fig. 6).…”
Section: Tuning the Response Of The Enzyme Electrodementioning
confidence: 99%
“…This ready supply of mediator is in direct contrast to thick-film enzyme electrodes which are usually cosubstrate limited. 35,37,38 Hence, with monolayer enzyme electrodes, the ready supply of mediator provides for efficient enzyme turnover, a high sensitivity per enzyme molecule and a broad dynamic range. The disadvantage however, is that the enzyme electrode is kinetically rather than mass-transport limited.…”
Section: A Reference Enzyme Electrodementioning
confidence: 99%
See 2 more Smart Citations
“…However, regardless of the enzyme specificity, the selectivity of these devices is compromised by electroactive species in the sample that may react directly at the transducer. The most frequent strategy to overcome this problem is to completely eliminate the interfering species by adsorption in permselective membranes [2 ± 4], multiple enzyme layers [5], mediators [6] and by on-line electrolysis [7,8].…”
Section: Introductionmentioning