1998
DOI: 10.1016/s0378-4347(97)00675-0
|View full text |Cite
|
Sign up to set email alerts
|

Recycling immunoaffinity chromatography for multiple analyte analysis in biological samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
29
0

Year Published

2000
2000
2008
2008

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 40 publications
(31 citation statements)
references
References 30 publications
2
29
0
Order By: Relevance
“…The small amount of blood available in the DBSS, combined with the low concentrations of many analytes relevant for monitoring inflammation, however, places high demands on the analytical methods. Multiplexed measurements of cytokines and coagulation factors by recycling immunoaffinity chromatography has been reported, but the method is highly specialized and laborious (24,33 ). We have developed a 25-plex high-capacity method for simultaneous determination of 23 cytokines, TREM-1, and CRP in two 3.2-mm punches of routinely collected neonatal DBSS, based on the commercially available Luminex xMAP technology.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The small amount of blood available in the DBSS, combined with the low concentrations of many analytes relevant for monitoring inflammation, however, places high demands on the analytical methods. Multiplexed measurements of cytokines and coagulation factors by recycling immunoaffinity chromatography has been reported, but the method is highly specialized and laborious (24,33 ). We have developed a 25-plex high-capacity method for simultaneous determination of 23 cytokines, TREM-1, and CRP in two 3.2-mm punches of routinely collected neonatal DBSS, based on the commercially available Luminex xMAP technology.…”
Section: Discussionmentioning
confidence: 99%
“…The specificity of the overall assay is therefore intrinsically high, which was also supported by the fact that we observed no cross-reaction within the panel or to other analytes tested. In principle, the method is more specific than recycling immunoaffinity chromatography, in which the specificity relies on reaction between usually polyclonal capture antibodies and fluorochrome-derivatized sample passing through the microcolumns (33 ). Recycling immunoaffinity chromatography would be expected to detect a larger fraction of cytokines interacting with blood proteins, based on the same argument.…”
Section: Discussionmentioning
confidence: 99%
“…The application of immunoaffinity techniques to analyze clinical samples has expanded over the past 5 years and the development of modification to these techniques, that enable multiple analytes to be measured, has advanced it even further (Nelson et al, 1998;Phillips and Krum, 1998 ). The technique can easily be adapted to automated and miniaturized systems therefore making it amenable to clinical and epidemiological studies.…”
Section: Discussionmentioning
confidence: 99%
“…Five immunoaffinity columns were connected to the selector enabling recycling of each sample consecutively through all five columns in a similar fashion to that previously described ( Phillips and Krum, 1998 ). The Scout also permitted elution of each individual column without disturbing the others.…”
Section: Instrumentationmentioning
confidence: 99%
See 1 more Smart Citation