2021
DOI: 10.3390/en14227685
|View full text |Cite
|
Sign up to set email alerts
|

Recurrence of Sub-Synchronous Oscillation Accident of Hornsea Wind Farm in UK and Its Suppression Strategy

Abstract: A large-scale power system breakdown in the United Kingdom caused blackouts in several important cities, losing about 3.2 percent of the load and affecting nearly 1 million power users on 9 August 2019. On the basis of the accident investigation report provided by the UK National Grid, the specific reasons for the sub-synchronous oscillation of Hornsea wind farm were analyzed. The Hornsea wind power system model was established by MATLAB simulation software to reproduce the accident. To solve this problem, bas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 22 publications
0
5
0
Order By: Relevance
“…The impact of each variable is quantified using Equation (18). By deducting the pre-disturbance energy from the post-disturbance energy for each data point and taking the average's absolute value, the required measure is derived.…”
Section: Sensitivity Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…The impact of each variable is quantified using Equation (18). By deducting the pre-disturbance energy from the post-disturbance energy for each data point and taking the average's absolute value, the required measure is derived.…”
Section: Sensitivity Analysismentioning
confidence: 99%
“…When dealing with SSO-disturbance-source location [16,17], the existing methods usually can only attribute the problem to a specific wind turbine, but lacks in-depth research on the internal control links of the wind turbine. This constraint could result in a lack of understanding of the oscillation's underlying cause, thus affecting effective control and management [18]. Based on the fine model of the D-PMSG converter, this paper not only analyzes the internal links of D-PMSG in detail but also accurately models its energy structure.…”
Section: Introductionmentioning
confidence: 99%
“…The total power is equal to the total installed capacity of the wind turbines. For example, a wind farm with fifty 2 MW generators is modeled as one 100 MW generator [26]. The data attachments of these systems are given in the appendices.…”
Section: Model Of Dfig-based Wind Farmmentioning
confidence: 99%
“…The planning and operation of today's power system need to be profoundly transformed to realize the above two improvements. For example, the blackout in the United Kingdom in 2019 was related to the decline of system inertia and anti-disturbance capability under a high proportion of renewable energy [10]. Renewable energy generators and related devices have very different operating characteristics from traditional devices, and the outputs of renewable energy are volatile and uncertain.…”
Section: Introductionmentioning
confidence: 99%