2010
DOI: 10.1016/j.ijleo.2009.11.004
|View full text |Cite
|
Sign up to set email alerts
|

Recording and reconstruction of digital Gabor hologram

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 16 publications
0
7
0
Order By: Relevance
“…For the simulated holograms, the agreement between the input and the measured optic paths was within 2% for spheres and 2% to 4% for thin rods. This suggests that twin image effects on phase images are not as serious as previously suggested [7]. The reason for this is the long distance between twin and real image for PSDIHM with light waves with the typical SOD used for high resolution imaging [1,6].…”
Section: Discussionmentioning
confidence: 55%
See 1 more Smart Citation
“…For the simulated holograms, the agreement between the input and the measured optic paths was within 2% for spheres and 2% to 4% for thin rods. This suggests that twin image effects on phase images are not as serious as previously suggested [7]. The reason for this is the long distance between twin and real image for PSDIHM with light waves with the typical SOD used for high resolution imaging [1,6].…”
Section: Discussionmentioning
confidence: 55%
“…The simplicity of DIHM, and, in particular, of PSDIHM, makes it of great interest to determine to what extent accurate optic path measurements on micrometer-sized objects are possible with PSDIHM. A theoretical and experimental analysis of PSDIHM hologram recording and reconstruction was recently published by Qu et al [7]. The authors suggested that because of twin-image problems that can arise in PSDIHM, phase reconstructions do not represent the quantitative phase delay induced by the specimen.…”
Section: Introductionmentioning
confidence: 99%
“…1, a spherical wave of wavelength λ emitting from a point source, illuminates an object, typically a distance a few thousand wavelengths from the source, and forms a highly magnified diffraction pattern on a screen much farther away. The diverging spherical wave can provide a geometrical magnification as compared with plane wave illumination [7] , as shown in Fig.…”
Section: Digital In-line Holographic Microscopymentioning
confidence: 99%
“…Recently, we demonstrated the suitability of digital holography for bacteria characterization [ 20 ]. This technique may be also useful for the examination of other biological samples [ 21 24 ]. Optical holography is a method that allows registration and reconstruction of both the amplitude and the phase of an optical field.…”
Section: Introductionmentioning
confidence: 99%
“…The simplest configuration is represented by digital in-line holographic microscopy (DIHM). This concept is based on a technique originally proposed by Gabor under the assumption of light scattering on an in-line illuminated object [ 21 23 ]. In this case, the interference occurs when the amplitude of the scattered wave is small compared with the amplitude of the non-scattered reference wave.…”
Section: Introductionmentioning
confidence: 99%