2019
DOI: 10.1111/dme.14073
|View full text |Cite
|
Sign up to set email alerts
|

Recommended pre‐analytical plasma glucose sampling methodology may distort gestational diabetes mellitus prevalence: implications for diagnostic thresholds

Abstract: Aim Current International Association of the Diabetes and Pregnancy Study Groups/World Health Organization gestational diabetes mellitus (GDM) diagnostic thresholds are based on a landmark study in which the pre-analytical plasma glucose sampling methodology is unclear. Worldwide, plasma glucose pre-analytical sampling methodology practices are divergent. We considered the effects of pre-analytical plasma glucose sampling methodology on GDM prevalence and gestational outcomes.Methods This is a retrospective ob… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
20
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(20 citation statements)
references
References 20 publications
(40 reference statements)
0
20
0
Order By: Relevance
“…Although well recognized in the biochemical research literature, one important issue that is too rarely discussed is the type of sample and the handling of samples before the assay of glucose or HbA 1c . The current recommendations and thresholds for diagnosing gestational diabetes are based on the HAPO study where the pre‐analytical sampling methodology was ‘left to the discretion of local sites’ . In some settings, it is likely that the pre‐analytical sampling methodology in the HAPO study did not prevent glycolysis, which could render the levels of these current diagnostic recommendations too low.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Although well recognized in the biochemical research literature, one important issue that is too rarely discussed is the type of sample and the handling of samples before the assay of glucose or HbA 1c . The current recommendations and thresholds for diagnosing gestational diabetes are based on the HAPO study where the pre‐analytical sampling methodology was ‘left to the discretion of local sites’ . In some settings, it is likely that the pre‐analytical sampling methodology in the HAPO study did not prevent glycolysis, which could render the levels of these current diagnostic recommendations too low.…”
mentioning
confidence: 99%
“…Song et al . studied 892 pregnant women, of whom 14% had gestational diabetes, using samples collected in sodium fluoride/potassium oxalate tubes, stored at room temperature . Using lyophilized citrate tubes reduces glycolysis and so measurements are higher than samples using sodium fluoride/potassium oxalate tubes stored for a similar time.…”
mentioning
confidence: 99%
“…To further categorise patients, all were given a Hyperglycaemia and Adverse Pregnancy Outcomes (HAPO) glucose composite score. Each patient was categorized according to HAPO glucose categories [13]:…”
Section: Gdm Classification and Composite Scorementioning
confidence: 99%
“…The range of fasting plasma glucose levels in a population was narrower than the 1 h and 2 h levels, each patient's OGTT results were scaled according to a measure with equivalent risks of adverse outcomes-the HAPO study's glucose categories (between 1 to 7) [13]. The HAPO glucose composite score for each patient was the sum of scores of maternal plasma glucose exposure at each OGTT time point.…”
Section: Gdm Classification and Composite Scorementioning
confidence: 99%
“…Our OGTTs were collected using sodium fluoride collected at room temperature and batched centrifuged 10 . This pre-analytical method has been recently documented, via the process of glycolysis, to lower reported OGTT fasting glucose levels by approximately 10% 10,23 . Therefore the adjusted lower and upper reference level of fasting glucose should be 10% higher -approximately 4.1 to 5.8 mmol/L.…”
Section: Capillary Blood Glucose Targets and Treatment Intensificatiomentioning