2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR) 2013
DOI: 10.1109/icorr.2013.6650486
|View full text |Cite
|
Sign up to set email alerts
|

Recognition of hand movements in a trans-radial amputated subject by sEMG

Abstract: Trans-radially amputated persons who own a myoelectric prosthesis have currently some control via surface electromyography (sEMG). However, the control systems are still limited (as they include very few movements) and not always natural (as the subject has to learn to associate movements of the muscles with the movements of the prosthesis). The Ninapro project tries helping the scientific community to overcome these limits through the creation of electromyography data sources to test machine learning algorith… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
12
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 14 publications
0
12
0
Order By: Relevance
“…Compared to conventional EMG data acquisition systems (as used in [15]- [17]) the Myo armband is highly convenient to use. The dry electrodes do not require exact placement and can be placed all at once, such that stroke survivors themselves can don the Myo armband.…”
Section: A System Characteristics and Advantagesmentioning
confidence: 99%
See 3 more Smart Citations
“…Compared to conventional EMG data acquisition systems (as used in [15]- [17]) the Myo armband is highly convenient to use. The dry electrodes do not require exact placement and can be placed all at once, such that stroke survivors themselves can don the Myo armband.…”
Section: A System Characteristics and Advantagesmentioning
confidence: 99%
“…Once the Myo armband is donned, the user is guided through a training routine, where the classifier is trained with desired gestures. Such training is necessary for every state of the art EMG system [15]- [18], as EMG is not an absolute measure and changes for different users and different sessions (electrode placement, fatigue of the user, etc.) [21].…”
Section: A System Characteristics and Advantagesmentioning
confidence: 99%
See 2 more Smart Citations
“…This database is a result of NINAPRO project [13] and can be downloaded from NINAWEB -the web interface of the NINAPRO project [14]. Two versions of the database were presented, as well as the various techniques used for data preprocessing, feature extraction, and hand posture classification [2], [15]- [16]. One of the techniques offered by NINAPRO project is the use of Principal Component Analysis (PCA) for feature extraction.…”
mentioning
confidence: 99%