Proceedings of 36th International Cosmic Ray Conference — PoS(ICRC2019) 2019
DOI: 10.22323/1.358.0128
|View full text |Cite
|
Sign up to set email alerts
|

Recent Progress on the GAPS Time of Flight System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 6 publications
0
7
0
Order By: Relevance
“…The inner ToF is a cube that surround the tracker system on top, bottom and lateral sides. All scintillators are 6.35 mm thick and 16 cm wide, with a variable lenght between 1.51 and 1.8 m. Each paddle system provides the measurement of energy deposit, time and longitudinal position along its largest dimension [10]. The tracker systems is made of 1440 Si(Li) detectors arranged in 10 evenly spaced planes [11][12][13][14].…”
Section: The Gaps Experimentsmentioning
confidence: 99%
“…The inner ToF is a cube that surround the tracker system on top, bottom and lateral sides. All scintillators are 6.35 mm thick and 16 cm wide, with a variable lenght between 1.51 and 1.8 m. Each paddle system provides the measurement of energy deposit, time and longitudinal position along its largest dimension [10]. The tracker systems is made of 1440 Si(Li) detectors arranged in 10 evenly spaced planes [11][12][13][14].…”
Section: The Gaps Experimentsmentioning
confidence: 99%
“…The ToF system consists of ∼ 160 plastic scintillator paddles [10] and is arranged in an outer Tof system and an inner Tof system (see Fig. 1 right).…”
Section: The Gaps Detectormentioning
confidence: 99%
“…The ToF system consists by ∼ 160 plastic scintillator paddles [12] and is arranged in and outer ToF system and an inner ToF system (see Figure 1).…”
Section: The Gaps Detectormentioning
confidence: 99%
“…In addition, this last trigger scheme requires that the TOF energy depositions are in the range of slow-moving |Z| = 1 or |Z| = 2 to reject minimally ionizing (high-velocity) and high-charge particles. This second configuration was optimal for selecting the annihilating antinuclei with an efficiency higher than 60% in the β range of scientific interest for the GAPS experiment, ∼ 0.2 to ∼ 0.6, while reducing the trigger rate down to less than 1 kHz from the expected MHz rate with the minimum bias trigger [12].…”