2006
DOI: 10.1016/s1076-5670(06)44001-5
|View full text |Cite
|
Sign up to set email alerts
|

Recent Progress in High Frequency Electron Cyclotron Resonance Ion Sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
32
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(32 citation statements)
references
References 104 publications
0
32
0
Order By: Relevance
“…1 In the past decade, the performance of ion source was improved dramatically. For example, the beam intensity of Ar 8+ was increased from several 100 eA to 2 emA.…”
Section: Introductionmentioning
confidence: 99%
“…1 In the past decade, the performance of ion source was improved dramatically. For example, the beam intensity of Ar 8+ was increased from several 100 eA to 2 emA.…”
Section: Introductionmentioning
confidence: 99%
“…The 24 GHz transmission line and rf coupling system to SECRAL are similar to that developed at SERSE source. 19,20 The 24 GHz transmission line from the gyrotron cabinet to the SECRAL source consists of arc detector, directional coupler, polarizer, mode converter from T 02 to T 01 , mode filter, compensator, dc breaker, 90°c orrugated bend, and bore-nitride microwave window, as shown in Fig. 4.…”
Section: Secral Preliminary Test Results With a 24 Ghz/7 Kw Gyrotmentioning
confidence: 99%
“…make it general, we now consider the typical magnetostatic profile relative to the case in which a single monochromatic wave at the frequency of 28 GHz is used to supply the source [3,[13][14][15][16]. Typical magnetic field profile on the z axis, relative to the case in which an electromagnetic wave at the frequency of 28 GHz is applied to a high-performance ion source.…”
Section: Parametermentioning
confidence: 99%
“…Typical magnetic field profile on the z axis, relative to the case in which an electromagnetic wave at the frequency of 28 GHz is applied to a high-performance ion source. Then, by taking into account the power values commonly required to feed the cavity in the considered case, suitable dimensions for it can be chosen as length L C = 0.6 m and radius a C = 0.08 m [3,[13][14][15][16]. Practical rules for the ion source operation [1][2][3] require that there be a plasma chamber large enough to obtain a suitable and not-too-high average power density within it.…”
Section: Parametermentioning
confidence: 99%
See 1 more Smart Citation