2017
DOI: 10.1107/s2059798317007859
|View full text |Cite
|
Sign up to set email alerts
|

Recent developments in theCCP-EMsoftware suite

Abstract: As part of its remit to provide computational support to the cryo-EM community, the Collaborative Computational Project for Electron cryoMicroscopy (CCP-EM) has produced a software framework which enables easy access to a range of programs and utilities. The resulting software suite incorporates contributions from different collaborators by encapsulating them in Python task wrappers, which are then made accessible via a user-friendly graphical user interface as well as a command-line interface suitable for scr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
306
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 338 publications
(306 citation statements)
references
References 55 publications
0
306
0
Order By: Relevance
“…We emphasize the importance of selecting appropriate levels of map blurring/sharpening, which may be facilitated by considering the behaviour of the average map amplitude at different resolutions, and the utility of simultaneously viewing multiple blurred/sharpened maps. These tools are available from within the CCP-EM interface (Burnley et al , 2017). …”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…We emphasize the importance of selecting appropriate levels of map blurring/sharpening, which may be facilitated by considering the behaviour of the average map amplitude at different resolutions, and the utility of simultaneously viewing multiple blurred/sharpened maps. These tools are available from within the CCP-EM interface (Burnley et al , 2017). …”
Section: Discussionmentioning
confidence: 99%
“…An array of blurred/sharpened maps can be output by REFMAC 5 and loaded into Coot automatically using the CCP-EM GUI (Burnley et al , 2017). However, note that this is for gaining intuition by visual inspection of the maps, and that at present REFMAC 5 will only use one map with one level of blurring/sharpening when performing the actual refinement.…”
Section: Blurring and Sharpeningmentioning
confidence: 99%
See 2 more Smart Citations
“…In crystallography, software packages such as Phenix.refine (Afonine et al, 2012), ARP/wARP (Lamzin et al, 2012) and GlobalPhasing PipeDream (Sharff et al, 2011) are designed to link and automate (in different ways and to a different extent, depending on the package) a structure solution stage, structure refinement step(s) and automated ligand fitting. While these packages are still mostly designed for use with x-ray diffraction data, modifications have been implemented to allow working with EM maps (for example CCPEM (Wood et al, 2015) (Burnley et al, 2017), Phenix CryoFit (Kirmizialtin et al, 2015) or Rosetta (Wang et al, 2016b)). Next steps should be linking these EM-specific variations into a single pipeline, which would ideally require minimal user input, and output a final model ready to be used for further drug design.…”