2006
DOI: 10.1016/j.trac.2006.03.002
|View full text |Cite
|
Sign up to set email alerts
|

Recent developments in comprehensive two-dimensional gas chromatography (GC×GC)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
121
0
8

Year Published

2008
2008
2017
2017

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 270 publications
(139 citation statements)
references
References 255 publications
0
121
0
8
Order By: Relevance
“…Observing the experimental conditions described, just two analytes (exemestane and furazabol metabolite) presented wrap-around, the phenomenon in which second-dimension peaks leave the second column in a modulation later than the one in which they entered the second column. 39 The classic wrap around profile for exemestane can be observed in Figure 1. Despite the wrap-around, a correct identification of analytes occurred in both cases without harming qualitative analysis.…”
Section: Resultsmentioning
confidence: 96%
“…Observing the experimental conditions described, just two analytes (exemestane and furazabol metabolite) presented wrap-around, the phenomenon in which second-dimension peaks leave the second column in a modulation later than the one in which they entered the second column. 39 The classic wrap around profile for exemestane can be observed in Figure 1. Despite the wrap-around, a correct identification of analytes occurred in both cases without harming qualitative analysis.…”
Section: Resultsmentioning
confidence: 96%
“…Fig. 7.34 shows one of the often-cited figures (Adahchour et al, 2006) that clearly illustrates how data from 2D-LC experiments are handled to produce 2D chromatograms. In the absence of software dedicated to the analysis of 2D-LC data, these steps can be accomplished by first exporting raw data from the chromatography data system, and then manipulating those data using any of a number of programming and analysis packages such as MatLab or Mathematica.…”
Section: Data Analysis Software and Quantitationmentioning
confidence: 99%
“…Most popular are the cryogenic modulators where fractions from the first column are trapped and released onto the second-dimension column by repeated cooling and heating of cryotraps. For a more detailed discussion on modulators for GC6GC, the reader is referred to the recent literature [25]. In LC6LC and LC6GC, interfaces can be constructed from standard LC valves.…”
Section: Principles Of Comprehensive Multidimensional Separationsmentioning
confidence: 99%