Advances in Electronic Packaging, Parts A, B, and C 2005
DOI: 10.1115/ipack2005-73291
|View full text |Cite
|
Sign up to set email alerts
|

Realization of Ultra-Wideband, High-Resolution TDR for Chip-Carrier Packages

Abstract: In this paper, a state of the art TDR with a rise time of 9ps was employed in the characterization of multi-layer ball-grid array (BGA) or land-grid array (LGA) packages. The hardware used for 9ps rising time was the Picosecond Pulse Lab’s 4022 Source Enhancement Module that reduces a standard TDR rise time of 35–40ps to 9ps. The high-resolution TDR can clearly indicates a root cause of a multi-layer package signal integrity problem (impedance mismatching) in vertical transitions consisting of vias and planes … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2011
2011
2012
2012

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 2 publications
0
2
0
Order By: Relevance
“…TDR uses a pulse generator and a high-speed oscilloscope to record in real time the reflection of a microwave signal by the open barrier [3,4]. TDR can at best provide resolution of about 1 mm making it most suitable for the high-pincount packages, such as quad flat package and ball grid array, but less convenient for smaller packages (less than 1 cm 2 ) [5], and more or less impossible to use on the latest development for connecting dies in wafer leveling packaging using microbumps.…”
Section: Time Domain Reflectometrymentioning
confidence: 99%
“…TDR uses a pulse generator and a high-speed oscilloscope to record in real time the reflection of a microwave signal by the open barrier [3,4]. TDR can at best provide resolution of about 1 mm making it most suitable for the high-pincount packages, such as quad flat package and ball grid array, but less convenient for smaller packages (less than 1 cm 2 ) [5], and more or less impossible to use on the latest development for connecting dies in wafer leveling packaging using microbumps.…”
Section: Time Domain Reflectometrymentioning
confidence: 99%
“…Such changes in characteristic impedance are caused by changes in the resistance, the inductance, or the capacitance of the wire pair. While initially developed to test cables, this has allowed TDR to also be used to measure soil humidity and detect soil movement [19], to locate microscopic defects in integrated circuits [11], and to recognize strains and fractures in buildings and bridges [31]. Engineers distinguish three termination types of TDR [33].…”
Section: Time Domain Reflectometrymentioning
confidence: 99%