2013 International Conference on Computer Communication and Informatics 2013
DOI: 10.1109/iccci.2013.6466136
|View full text |Cite
|
Sign up to set email alerts
|

Realization of cascaded H-bridge 5-Level multilevel inverter as Dynamic Voltage Restorer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 8 publications
0
5
0
Order By: Relevance
“…The (7) gives the relation between voltages at the LV winding and pole. Based on the state of conduction of swiches in VSC-1 and VSC-2, the voltages occur at Pole are decided.…”
Section: Wherementioning
confidence: 99%
See 1 more Smart Citation
“…The (7) gives the relation between voltages at the LV winding and pole. Based on the state of conduction of swiches in VSC-1 and VSC-2, the voltages occur at Pole are decided.…”
Section: Wherementioning
confidence: 99%
“…The distorted voltages and voltage sags at the system side caused by the faults in the power transmission system are corrected by the second type which is the series connected device, which has an edge over the Int J Pow Elec & Dri Syst ISSN: 2088-8694  Induction drive system with DSTATCOM based asymmetric twin converter (P Anusha) 1827 shunt type [4], these qualities in quality of power might lead to irregular operations of amenities or even the devices with protection are tripped. Generation or Absorption of Reactive Power Control is done by the use of converters employing technology of FACTS device which is linked in parallel to the system of power known as static synchronous compensator (STATCOM) [5][6][7]. Injection of Reactive power to the power system makes the STATCOM works in the capacitive mode.…”
Section: Introductionmentioning
confidence: 99%
“…With the advancement of high power semiconductor methodology applications to power distribution systems, advanced static compensation schemes for mitigation of distribution side concerns a distributed static compensation scheme (DSTATCOM). It is exploited as a shunt device which can alleviate the currents related PQ concerns with voltage and current controlled mode of operations is proposed in [2,3]. Extensively current driven voltage source inverters (VSI) advanced multilevel inverters in [4] based active devices are preferred to engage the PCC concerns by using efficient control strategies.…”
Section: Introductionmentioning
confidence: 99%
“…The RES may be an AC source such as wind energy generation or a DC source such as PV array & fuel cell with high rated converter coupled to dc-link. Hence, the energy generated from the proposed renewable energy source needs power conditioning like high rated converters to get high voltage as well as energy conversion before connecting to conditioner [5] [6]. To minimize the intricate of the premature conditioner combination, the converter type series active power filter, which comprise very high impedance for high-frequency harmonics, is consort by a shunt resonant type passive power filter to furnish a way for the harmonic currents of the distributed load, permits an ameliorate all over the performance of plain series active filter based conditioner and the extended their capabilities to include voltage & current harmonic elimination.…”
Section: Introductionmentioning
confidence: 99%