2008
DOI: 10.1016/j.ultrasmedbio.2008.01.004
|View full text |Cite
|
Sign up to set email alerts
|

Real-Time Ultrasound Elastography: Its Potential Role in Assessment of Breast Lesions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
54
0
4

Year Published

2009
2009
2020
2020

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 100 publications
(60 citation statements)
references
References 14 publications
2
54
0
4
Order By: Relevance
“…In this 5 score classification system color spectrum changes are taken in a dynamic form, and it is suggested to have a higher specificity in differential diagnosis. This scoring system has been used in several studies and the effectiveness of elastography as an adjunct to B mode ultrasonography was investigated (6)(7)(8)(9)(10)(11)(12)(13)(14)(15). Modified versions of Ueno's classification by Scaperrotta et al (16) and Regini et al (17) also confirmed higher specificity for US elastography.…”
Section: Discussionmentioning
confidence: 98%
“…In this 5 score classification system color spectrum changes are taken in a dynamic form, and it is suggested to have a higher specificity in differential diagnosis. This scoring system has been used in several studies and the effectiveness of elastography as an adjunct to B mode ultrasonography was investigated (6)(7)(8)(9)(10)(11)(12)(13)(14)(15). Modified versions of Ueno's classification by Scaperrotta et al (16) and Regini et al (17) also confirmed higher specificity for US elastography.…”
Section: Discussionmentioning
confidence: 98%
“…The velocity information produces a color image of the stiffness and measures SWE features such as the minimum elasticity (Emin), mean elasticity (Emean), and maximum elasticity (Emax) and ratio of lesion-to-fat (SWE ratio) elasticity in a region of interest (1,2,(9)(10)(11)(12)(13). Using quantitative elasticity data, SWE thus provides more objective information than static elastography and enhanced lesion differentiation than conventional grayscale US (14)(15)(16)(17). Based on these characteristics, quantitative US elastography using SWE is expected to have higher reproducibility.…”
Section: Intra-and Interobserver Reproducibility Of Shear Wave Elastomentioning
confidence: 99%
“…In most cases, compression to the area of interest is manually applied, with some scanners relying on internal patient movement such as respiratory or cardiac motion. [10][11][12][13] The commercially-available intravascular ultrasound (IVUS) system (EndoSonics, USA) investigates the morphology of the coronary wall and plaque by observing the induced strain in the vascular tissue via different levels of the intraluminal pressure.…”
Section: Static Elastographymentioning
confidence: 99%