2008
DOI: 10.1016/j.radonc.2008.03.013
|View full text |Cite
|
Sign up to set email alerts
|

Real-time tumor-tracking radiotherapy for adrenal tumors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
53
0
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 69 publications
(57 citation statements)
references
References 30 publications
3
53
0
1
Order By: Relevance
“…Katoh et al 23 investigated three-dimensional tumour motion of the fiducial marker inserted in the adrenal metastasis resulting in a large marker shift related to organ movement, greater in the craniocaudal direction (1 cm). There was no statistically significant difference in the average amplitude between the supine and prone positions along the three axes, as well as with regard to the distance between the stomach, the duodenum and the tumour.…”
Section: Technical Issuesmentioning
confidence: 99%
“…Katoh et al 23 investigated three-dimensional tumour motion of the fiducial marker inserted in the adrenal metastasis resulting in a large marker shift related to organ movement, greater in the craniocaudal direction (1 cm). There was no statistically significant difference in the average amplitude between the supine and prone positions along the three axes, as well as with regard to the distance between the stomach, the duodenum and the tumour.…”
Section: Technical Issuesmentioning
confidence: 99%
“…39 There were also no differences in the minimum distances of implanted fiducial markers to the stomach or duodenum. As such, the supine position became standard as it is more comfortable for the patient.…”
Section: Simulationmentioning
confidence: 88%
“…As such, the supine position became standard as it is more comfortable for the patient. 39 All patients in modern series had 4D CT simulation scans to enable visualization of the maximum movement of the lesion in relation to normal structures. 37 Oral and intravenous contrast were often employed.…”
Section: Simulationmentioning
confidence: 99%
See 1 more Smart Citation
“…Hastalara ortalama 50 Gy doz verilmiş olup, %73 hastada parsiyel yanıt elde edilmiş ve median sağkalım 10 ay bulunmuştur. [19] Katoh ve ark.nın [20] yaptıkları bir çalışmada fiducial işa-retleyici kullanılarak SBRT uygulanan 10 hastaya sekiz fraksiyonda 48 Gy doz uygulanmıştır. Hastalarda bir yıllık sağkalım %78, lokal kontrol %100 bulunmuştur.…”
Section: Hastalar Ve Yöntemunclassified