Abstract:The characteristics of an internal slurry were analyzed during ball milling, which is commonly utilized in ceramic processing. We used a device with a capacity of 50 L because this is the size employed in industries, and built a circulation system to collect the slurry during the milling process. The properties of the slurry were characterized in terms of their particle size and viscosity, while vibration data were collected from the side of the ball mill drum in real time. A fast Fourier transform was perform… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.