2017 IEEE 8th International Symposium on Power Electronics for Distributed Generation Systems (PEDG) 2017
DOI: 10.1109/pedg.2017.7972525
|View full text |Cite
|
Sign up to set email alerts
|

Real Time Simulation of Dynamic Voltage Restorer (DVR) utilizing RTDS and dSPACE

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 26 publications
0
1
0
Order By: Relevance
“…This characteristic assumes that the electrical power supplied by a conventional synchronous machine is predominantly related to the energy that is supplied to that machine by the primary motor [25]. In this sense, for the frequency support was implemented a control system of the type droop P − f, given by (16), where R F is the statism of the droop control in steady state.…”
Section: Frequency Supportmentioning
confidence: 99%
See 1 more Smart Citation
“…This characteristic assumes that the electrical power supplied by a conventional synchronous machine is predominantly related to the energy that is supplied to that machine by the primary motor [25]. In this sense, for the frequency support was implemented a control system of the type droop P − f, given by (16), where R F is the statism of the droop control in steady state.…”
Section: Frequency Supportmentioning
confidence: 99%
“…Energies 2023, 16, 7379 2 of 34 Despite the steady increase in Distributed Generation (DG) connection by Renewable Energy Sources (RES), conventional synchronous generators will continue to play a significant role in power generation, especially in countries with vast water resources. The seasonal variability of renewable energy resources will impact the inertia of the electricity system as its contribution increases.…”
Section: Introductionmentioning
confidence: 99%
“…The dynamic voltage controller as shown in Fig. 1 interface at a PCC between the power supply source and the feeder of the sensitive load, which is essentially VSI and capable to inject/absorb additional real and imaginary power to/from the distribution network to avoid sensitive load from tripping by compensating of voltage dip/rise via injecting voltage in series with main source [21].…”
Section: Figure 1: Position and Elements Of The Series Voltage Restorermentioning
confidence: 99%