Real-Time Monitoring of Blood Pressure Using Digitalized Pulse Arrival Time Calculation Technology for Prompt Detection of Sudden Hypertensive Episodes During Laryngeal Microsurgery: Retrospective Observational Study

Abstract: Background Laryngeal microsurgery (LMS) is often accompanied by a sudden increase in blood pressure (BP) during surgery because of stimulation around the larynx. This sudden change in the hemodynamic status is not immediately reflected in a casual cuff-type measurement that takes intermittent readings every 3 to 5 min. Objective This study aimed to investigate the potential of pulse arrival time (PAT) as a marker for a BP surge, which usually occurs in … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 40 publications
0
6
0
Order By: Relevance
“…Vocal fold polyps are one of the top five diseases of the larynx with an incidence of 404/100,000, 1 and laryngeal microsurgery is the treatment of choice for most patients 2 . Although the duration of surgery is relatively short, the noxious stimulus caused by the placement of suspension laryngoscope often triggers strong the vagal reflex, leading to severe cardiovascular adverse reactions 3,4 . Previous studies have shown that the incidence of vagal reflexes during supported laryngoscopic vocal cord polypectomy can be as high as 15% 5 .…”
Section: Introductionmentioning
confidence: 99%
“…Vocal fold polyps are one of the top five diseases of the larynx with an incidence of 404/100,000, 1 and laryngeal microsurgery is the treatment of choice for most patients 2 . Although the duration of surgery is relatively short, the noxious stimulus caused by the placement of suspension laryngoscope often triggers strong the vagal reflex, leading to severe cardiovascular adverse reactions 3,4 . Previous studies have shown that the incidence of vagal reflexes during supported laryngoscopic vocal cord polypectomy can be as high as 15% 5 .…”
Section: Introductionmentioning
confidence: 99%
“…The pulse arrival time (PAT) parameter, which indicates the time taken for the pulse waveforms to traverse from the heart to a distal site, is often used in a paired sensing system 7 . PAT is determined using fiducial points, including the R-wave and the systolic peak of the ECG and PPG waveforms 8,9 . In addition, unlike a sphygmomanometer, an ECG-PPG paired sensing system can continuously monitor BP 8,10 .…”
Section: Introductionmentioning
confidence: 99%
“…The challenge is the relatively short operating time that demands patient quick awaking and recovery of muscle power [ 2 ]. However, the paradox is that the larynx is a highly reflexogenic region, the stimulation of the pharynx gives rise to sympathetic excitation and the consequence is that the events such as tachycardia, hypertension, and arrhythmias may happen; which means that deep anesthesia is required to suppress stress response [ 6 ]. So, exploring a new technique that could inhibit the stress response and promote quick awaking is meaningful for the patients undergoing SLVCP.…”
Section: Introductionmentioning