2012
DOI: 10.1186/1532-429x-14-s1-p227
|View full text |Cite
|
Sign up to set email alerts
|

Real time measurement of cardiac pressure-volume relationships

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2014
2014
2014
2014

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 20 publications
0
3
0
Order By: Relevance
“…The proposed method uses a smaller set of projections in a KWIC filter to reduce the problems associated with data sharing and subsequently removes the occurring aliasing artifacts using parallel imaging. A similar approach has already been used for cardiac imaging . An important parameter to be considered is the band‐width of the KWIC filter, which has to be adjusted for different applications, according to the dynamics of the data at hand and the parallel imaging capacity of the receiver array.…”
Section: Discussionmentioning
confidence: 99%
“…The proposed method uses a smaller set of projections in a KWIC filter to reduce the problems associated with data sharing and subsequently removes the occurring aliasing artifacts using parallel imaging. A similar approach has already been used for cardiac imaging . An important parameter to be considered is the band‐width of the KWIC filter, which has to be adjusted for different applications, according to the dynamics of the data at hand and the parallel imaging capacity of the receiver array.…”
Section: Discussionmentioning
confidence: 99%
“…Loadindependent indices of ventricular function such as end-systolic pressure-volume and end-diastolic pressure-volume relationships are of particular interest, 28 and novel MRI techniques that serially quantify cardiac elastance and compliance in vivo will be used in future studies as an added metric of therapeutic efficacy. Because this study represents a paired comparison of ventricular function in the acute setting, we standardized device parameters across all treatment animals.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, miniaturization of the external gas exchange pump will allow for longterm assessment of ventricular size, strain/stress, and border zone function after device placement and activation. Loadindependent indices of ventricular function such as end-systolic pressure-volume and end-diastolic pressure-volume relationships are of particular interest, 28 and novel MRI techniques that serially quantify cardiac elastance and compliance in vivo will be used in future studies as an added metric of therapeutic efficacy.…”
Section: Discussionmentioning
confidence: 99%