2014
DOI: 10.1016/j.ijepes.2014.01.021
|View full text |Cite
|
Sign up to set email alerts
|

Real time implementation of PI and fuzzy logic controller based 3-phase 4-wire interleaved buck active power filter for mitigation of harmonics with id–iq control strategy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
31
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 44 publications
(31 citation statements)
references
References 22 publications
0
31
0
Order By: Relevance
“…In case of MSRF method, the θ is generated by a simplified unit vector generation scheme instead of PLL circuit as used in case of SRF method . The block diagram representation of the MSRF scheme is shown in Figure B .…”
Section: Modeling Of Sapfmentioning
confidence: 99%
“…In case of MSRF method, the θ is generated by a simplified unit vector generation scheme instead of PLL circuit as used in case of SRF method . The block diagram representation of the MSRF scheme is shown in Figure B .…”
Section: Modeling Of Sapfmentioning
confidence: 99%
“…> > > > > > > > > = > > > > > > > > > ; (12) where e 2 (t) and e 3 (t) are the system disturbances and e 1 (t) is the lumped uncertainty and y is the output. Assume that these disturbances are having boundaries.…”
Section: Sliding Mode Controllersmentioning
confidence: 99%
“…Hong et al developed a prototype of interleaved dual buck full‐bridge 3‐level inverter for grid‐connected system. Patel and Panda introduced interleaved topology to overcome the shoot‐through problem in the area of active filters and developed the model using OPAL‐RT platform. However, the practical considerations of the development are not taken into account at that point of time.…”
Section: Introductionmentioning
confidence: 99%
“…It consists of three single-phase H-bridge inverter. The advantage of this topology is that the voltage across in each H-bridge interleaved buck inverter appears the singlephase voltage only and hence the reference DC link voltage needed is reduced by √3 times as compared to 3phase interleaved buck inverter with split capacitor topology [10]. Here, in this proposed topology only one DC-link capacitor voltage is required by the p-q control strategy, out of the three individual phases for reference Where i sa , i sb , i sc and i sn represent the corresponding source phase currents and source neutral current.…”
Section: B Proposed 3-phase 4-wire H-bridge Interleaved Buck Active mentioning
confidence: 99%
“…In reference paper [10], the split capacitor IB-APF has been developed, but can be used for low power application. To overcome this limitation, H-bridge IB-APF is implemented here in 3-phase 4-wire system for high voltage with medium-to-high power application.…”
Section: Introductionmentioning
confidence: 99%