2012
DOI: 10.1109/tsg.2012.2200702
|View full text |Cite
|
Sign up to set email alerts
|

Real-Time Energy Management Algorithm for Mitigation of Pulse Loads in Hybrid Microgrids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
119
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 177 publications
(119 citation statements)
references
References 26 publications
0
119
0
Order By: Relevance
“…The term "hybrid AC/DC microgrid" conventionally refers to a microgrid that includes a conventional AC distribution system, as illustrated in Figure 1, and an extension DC grid that is connected to the AC system through one or more parallel bidirectional converters, as illustrated in Figure 2 [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21]. In the present study, a new design for a hybrid AC/DC microgrid is proposed, while the two back-to-back (B2B) series and parallel converters are connected between AC and DC microgrids, as shown in Figure 3.…”
Section: Hybrid Ac/dc Microgrid Structurementioning
confidence: 99%
See 2 more Smart Citations
“…The term "hybrid AC/DC microgrid" conventionally refers to a microgrid that includes a conventional AC distribution system, as illustrated in Figure 1, and an extension DC grid that is connected to the AC system through one or more parallel bidirectional converters, as illustrated in Figure 2 [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21]. In the present study, a new design for a hybrid AC/DC microgrid is proposed, while the two back-to-back (B2B) series and parallel converters are connected between AC and DC microgrids, as shown in Figure 3.…”
Section: Hybrid Ac/dc Microgrid Structurementioning
confidence: 99%
“…The pu values of the three-phase ideal voltages are calculated, as shown in Eq. (9). The amount of the voltage that should be injected into the grid by the compensator is calculated by comparing the ideal obtained voltages and the instantaneous ones, as shown in Eq.…”
Section: Series Compensator Control Designmentioning
confidence: 99%
See 1 more Smart Citation
“…[3,6] to protect the components of CESS. In the intensive study, namely the coordination control of various ESSs, only the literature [12] discusses overcharge and over discharge protection control scheme when the SOC of two ESSs are in the different states, and only the literature [15] describes that the power-type storage remains full charge to satisfy the pulse load in microgrid, and only the literatures [1] and [6] propose that the SOC of power-type storage should be maintained at its intermediate value to maintain a certain power adjustment capability all the time.…”
Section: Introductionmentioning
confidence: 99%
“…This author, along with others has developed a real time energy management to mitigate such conditions as published by Ahmed, Salehi, et. al [186]. In this work, the system loads are based on hourly average variations and can be considered as lowfrequency variation, whereas power transients, which is sustained for minutes, seconds, or milliseconds come under the high-frequency segment.…”
Section: Energy Management In Hybrid Microgridsmentioning
confidence: 99%