2007
DOI: 10.1016/j.bioelechem.2006.11.001
|View full text |Cite
|
Sign up to set email alerts
|

Real time electroporation control for accurate and safe in vivo non-viral gene therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

7
115
0
3

Year Published

2008
2008
2024
2024

Publication Types

Select...
6
1
1

Relationship

4
4

Authors

Journals

citations
Cited by 138 publications
(130 citation statements)
references
References 29 publications
7
115
0
3
Order By: Relevance
“…Our algorithm is a step towards effective treatment planning, not only in clinical ECT, but also in other electroporation based treatments, such as gene electrotransfer, transdermal drug delivery and irreversible tumor ablation. [16][17][18] …”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Our algorithm is a step towards effective treatment planning, not only in clinical ECT, but also in other electroporation based treatments, such as gene electrotransfer, transdermal drug delivery and irreversible tumor ablation. [16][17][18] …”
Section: Discussionmentioning
confidence: 99%
“…19 The values were chosen in accordance with previous measurements of tumor and tissue conductivity and models of subcutaneous tumor and skin electroporation. 13,16,20 The electric field distribution was calculated for three different electrode geometries: two different parallel needle electrode arrays (Figure 2a,b) and a hexagonal electrode array with two different electrode polarities (Figure 2c,d). These geometries and polarities were chosen because they are frequently used in ECT research and therapy.…”
Section: Tissue Properties and Model Geometrymentioning
confidence: 99%
See 1 more Smart Citation
“…Conductivity values of the different tissues are taken from the literature (Gabriel et al 1996;Haemmerich et al 2009), while the change of conductivity due to electroporation is set to a factor of 3.5 (Cukjati et al 2007). The magnitude of conductivity change has also recently been confirmed on ex vivo chicken liver using magnetic resonance electrical impendance tomographic imaging (Kranjc et al 2012).…”
Section: Electric Field Distribution Calculation and Optimizationmentioning
confidence: 99%
“…Perspectivas apontam para o uso de correntes de alta voltagem e mínimo tempo de aplicação, seguidos de pulsos de baixa voltagem e longo tempo de duração (CUKJATI et al, 2007); (PAVSELJ e PREAT, 2005).…”
Section: As Correntes Elétricas Na Eletroporaçãounclassified