2021
DOI: 10.1021/acssensors.1c01580
|View full text |Cite
|
Sign up to set email alerts
|

Real-Time Detection and Control of Microchannel Resonance Frequency in Acoustic Trapping Systems by Monitoring Amplifier Supply Currents

Abstract: The utilization of bulk acoustic waves from a piezoelectric transducer for selective particle trapping under flow in a microchannel is limited by the high sensitivity of the resonance frequency to tolerances in device geometry, drift during trapping, and variations in the local flow or sample conditions in each channel. This is addressed by detecting the resonance condition based on the impedance minimum obtained by monitoring the amplitude of the stimulation voltage across the piezo transducer and utilizing r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 42 publications
0
12
0
Order By: Relevance
“…The physical and psychological conditions of pregnant women will inevitably affect the healthy development of the fetus. Ultrasound is used to monitor the frequency of emitted and received sound waves [ 31 ]. The difference between the frequencies of the emitted and received sound waves is represented by the Doppler frequency shift f D , and the calculation is shown as follows: …”
Section: Establishment Of a Nursing Platform For Obstetrics And Gynec...mentioning
confidence: 99%
“…The physical and psychological conditions of pregnant women will inevitably affect the healthy development of the fetus. Ultrasound is used to monitor the frequency of emitted and received sound waves [ 31 ]. The difference between the frequencies of the emitted and received sound waves is represented by the Doppler frequency shift f D , and the calculation is shown as follows: …”
Section: Establishment Of a Nursing Platform For Obstetrics And Gynec...mentioning
confidence: 99%
“…Goddard et al 27 Impedance 2006 Suthanthiraraj et al 28 Impedance 2012 Kalb et al 29 Impedance 2018 Farmehini et al 30 Electric current 2021…”
Section: Measured Parameter Year Publishedmentioning
confidence: 99%
“…Two parameters are currently being used to measure the resonance, which are the impedance of the system [27][28][29] or the electric current. 30 The measured resonance behavior of the system is then used to tune the excitation frequency of the driving piezoelectric transducer. These state of the art methods of which parameters can be used to implement a FCL are summarized in Table 1.…”
Section: Introductionmentioning
confidence: 99%
“…[16] Hence, microfluidic separation based on multiple biophysical criteria integrated with on-chip phenotypic analysis at single-cell sensitivity can enhance discrimination of cellular phenotypes and be applied to enrich for minority subpopulations. [17,18,19] This phenotypic information is essential for device design, active control of separation conditions, [20] and sample choice to improve versatility of the workflow [21,22] and discrimination ability of the separation.…”
Section: Introductionmentioning
confidence: 99%