Real-time and visible monitoring of structural damage using mechanoresponsive luminogen: recent progress and perspectives

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 128 publications
0
5
0
Order By: Relevance
“…Based on the location of luminescence emission, the crack length can be determined thus the fracture toughness can be calculated. However, due to instantaneous luminescence response, it is inconvenient to detect and transmit the ML signals 30,31 . Moreover, ML materials usually have poor film‐forming capability, which are often mixed with epoxy resin and coated on the surface of structures.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Based on the location of luminescence emission, the crack length can be determined thus the fracture toughness can be calculated. However, due to instantaneous luminescence response, it is inconvenient to detect and transmit the ML signals 30,31 . Moreover, ML materials usually have poor film‐forming capability, which are often mixed with epoxy resin and coated on the surface of structures.…”
Section: Introductionmentioning
confidence: 99%
“…However, due to instantaneous luminescence response, it is inconvenient to detect and transmit the ML signals. 30,31 Moreover, ML materials usually have poor film-forming capability, which are often mixed with epoxy resin and coated on the surface of structures. Interface debonding between resin and structures is easy to occur under fatigue loading, restricting the application of ML-based detection method for fatigue damage.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the ML-based on-site detection system needs high-speed camera to receive ML signal, which brings inconvenience to ML signal acquisition and transmission. [20,21] Compared with ML response, the duration of MCL response can last longer, which is convenient to receive and transmit the luminance. Currently, most research are focused on synthesis and luminescence mechanisms of MCL materials (i.e., polymers, photonic crystals, and molecules), less attention has been paid to detect the structural damage.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the ML‐based on‐site detection system needs high‐speed camera to receive ML signal, which brings inconvenience to ML signal acquisition and transmission. [ 20,21 ]…”
Section: Introductionmentioning
confidence: 99%
“…6 Compared with other materials, the ML materials with the characteristics of fast response speed, visualization and high repeatability have been widely used in the fields of stress sensing, structural health monitoring and luminescence anti-counterfeiting. [7][8][9][10][11][12] Therefore, it is important to review the principles, performance improvement and application development of ML materials, as shown in Fig. 1.…”
Section: Introductionmentioning
confidence: 99%