2015
DOI: 10.5890/jand.2015.09.009
|View full text |Cite
|
Sign up to set email alerts
|

Real-time 2D Concentration Measurement of CH4 in Oscillating Flames Using CT Tunable Diode Laser Absorption Spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…Two dimensional (2D) temperature and concentration maps can be obtained by combining the TDLAS method with a set of individual detectors or a focal planar array (FPA) detector. Kamimoto et al obtained 2D CH 4 concentration distributions using a 16 path TDLAS measurement cell [149]. In another study from the same group, FB lasers at 1.388 and 1.635 µm were used to measure water vapor, and CH 4 concentration, respectively.…”
Section: Tunable Diode Laser Absorption Spectroscopy (Tdlas)mentioning
confidence: 99%
“…Two dimensional (2D) temperature and concentration maps can be obtained by combining the TDLAS method with a set of individual detectors or a focal planar array (FPA) detector. Kamimoto et al obtained 2D CH 4 concentration distributions using a 16 path TDLAS measurement cell [149]. In another study from the same group, FB lasers at 1.388 and 1.635 µm were used to measure water vapor, and CH 4 concentration, respectively.…”
Section: Tunable Diode Laser Absorption Spectroscopy (Tdlas)mentioning
confidence: 99%
“…The external cavity type laser diode was split using the fiber splitter to 16 laser paths. 22,23 The absorption signals of 16 paths were detected and recorded simultaneously. The CT reconstruction rate was 1 ms/image using the absorption spectra with 30 times average.…”
Section: Experimental Systemmentioning
confidence: 99%
“…Recently, combination of computed tomography (CT) and TDLAS has been studied and applied for two-dimensional (2D) measurements of temperature and concentration in combustion processes. 1524 In past studies, H 2 O absorption spectra using narrow wavelength range scanning lasers were used for 2D temperature measurement. 2024 However, these lasers are not applicable for temperature measurement in high-pressure condition, such as 1.0–5.0 MPa.…”
Section: Introductionmentioning
confidence: 99%
“…The temperature and species concentration at each analysis grid are determined using a multifunction minimization method to reduce the spectral fitting error, as shown in Figure 5. The measurement errors are induced by a lot of factors, such as number of beams, view angles, CT-algorism, uncertainty of spectral database, and so on [7][8][9][10][11][12][13][14][15].…”
Section: Temperature Sensingmentioning
confidence: 99%
“…The CT-TDLAS method has been applied to the oscillating flames to measure the timeresolved 2D temperature and concentration distributions [9,11]. Figure 13 shows the experimental setup of time-resolved 2D temperature and CH 4 concentration measurements using CT-TDLAS in an oscillating CH 4 -Air Bunsen-type flame.…”
Section: Burner and Plant Applicationsmentioning
confidence: 99%