2020
DOI: 10.3390/pharmaceutics12040380
|View full text |Cite
|
Sign up to set email alerts
|

Real Life Population Pharmacokinetics Modelling of Eight Factors VIII in Patients with Severe Haemophilia A: Is It Always Relevant to Switch to an Extended Half-Life?

Abstract: We retrospectively analysed the data files of 171 adults and 87 children/adolescents with severe haemophilia, except for 14 patients (moderate; minor) (1), to develop a global population pharmacokinetic (PK) model for eight factors VIII (FVIII) that could estimate individual PK parameters for targeting the desired level of FVIII activity (FVIII:C); and (2) to compare half-life (HL) in patients switching from a standard half-life (SHL) to an extended half-life (EHL) and evaluate the relevance of the switch. One… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 28 publications
(40 reference statements)
2
6
0
Order By: Relevance
“…The estimated CL in a 66.7 kg patient was 1.74 dL/h, which is within the range reported by other studies (1.51-2.76 dL/h). [7][8][9][10][13][14][15][16]21,22] The estimated terminal half-life of 13.35 h is comparable to the values previously reported in recombinant, full length FVIII (11.69-13.79 h) (Supplementary Table 1). [7,9,10,21] Additionally, our estimated clearance and half-life was consistent with the values obtained from Japanese patients.…”
Section: F I G U R E 1 Goodness-of-fit Plots For the Final Pk Model (...supporting
confidence: 83%
“…The estimated CL in a 66.7 kg patient was 1.74 dL/h, which is within the range reported by other studies (1.51-2.76 dL/h). [7][8][9][10][13][14][15][16]21,22] The estimated terminal half-life of 13.35 h is comparable to the values previously reported in recombinant, full length FVIII (11.69-13.79 h) (Supplementary Table 1). [7,9,10,21] Additionally, our estimated clearance and half-life was consistent with the values obtained from Japanese patients.…”
Section: F I G U R E 1 Goodness-of-fit Plots For the Final Pk Model (...supporting
confidence: 83%
“…Of these 20, 6 combined data of multiple concentrates. 11,[18][19][20][21][22] Eleven publications described a population PK model for a SHL FVIII concentrate, 8 publications for an EHL FVIII concentrate, and 1 publication for both SHL and EHL FVIII concentrates.…”
Section: Fviii Population Pk Modelsmentioning
confidence: 99%
“…Ishihara et al [ 40 ] and Soraluce et al [ 41 ] use the industry standard parametric version of NONMEM. Allard et al [ 42 ] uses the stochastic approximation expectation maximization method (SAEM). NPAG can run any problem that is run by any of these programs.…”
Section: Supplementary Materialsmentioning
confidence: 99%