2001
DOI: 10.1016/s0039-9140(00)00566-x
|View full text |Cite
|
Sign up to set email alerts
|

Reagentless biosensor for isocitrate using one step modified Pt-Ir microelectrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

2002
2002
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 16 publications
1
8
0
Order By: Relevance
“…This behavior can be explained by the energy necessary to oxidize the mediator excess, damaging the formation of the film. These resulted were observed also in the work developed for Pereira et al 55 On the other hand for 10 min immersed electrode the values of current intensity increased proportionally with the NADH concentration and presented two linear range: (1 st fit -lower concentration and 2 nd fit -high concentrations) (Figure 4). The sensitivity was defined by slope of the fitted line as 3.0×10 -3 and 1.0×10 -3 μA per mol L and R was 0.995 and 0.969 for lower and high concentrations, respectively.…”
Section: Stability Of the Film Formed By Sol-gel Methodssupporting
confidence: 81%
See 1 more Smart Citation
“…This behavior can be explained by the energy necessary to oxidize the mediator excess, damaging the formation of the film. These resulted were observed also in the work developed for Pereira et al 55 On the other hand for 10 min immersed electrode the values of current intensity increased proportionally with the NADH concentration and presented two linear range: (1 st fit -lower concentration and 2 nd fit -high concentrations) (Figure 4). The sensitivity was defined by slope of the fitted line as 3.0×10 -3 and 1.0×10 -3 μA per mol L and R was 0.995 and 0.969 for lower and high concentrations, respectively.…”
Section: Stability Of the Film Formed By Sol-gel Methodssupporting
confidence: 81%
“…The PPy/MB modified electrode surface was prepared following the literature procedure, 55 which describes the use of Pt-Ir microelectrode, as work electrode and the mediator MB, concluding that the film formed above 0.600V would provides the superoxidation of the polypyrrol provoking bad definition in the signal of oxidation of the present mediator in the film.…”
Section: Modification Of the Glassy Carbon Electrode Surface By Electmentioning
confidence: 99%
“…Various strategies, e.g. adsorption [14,15], electropolymerization [16] and entrapment in a polymer matrix [17,18], have been adopted to anchor MB on the electrode surfaces. Among them, the direct adsorption of MB on carbon surfaces (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…The latter retained their antigenic activity and were used for immunosensing of antibodies recognizing Rhesus blood group antigen. The co-immobilization of enzyme (isocitrate dehydrogenase), coenzyme (NADP + ), and redox mediator (Meldola's blue) was also successfully carried out on a Pt-Ir microelectrode (150 µm in diameter) [29]. In addition, it was possible to optimize the resulting microbiosensor configuration for isocitrate determination in terms of film thickness, amount of immobilized mediator, and enzyme and coenzyme loading.…”
Section: Use Of Conducting Polymer Filmsmentioning
confidence: 99%