Reactions of Selenium and Oxygen. Matrix Infrared Spectra and Density Functional Calculations of Novel SexOy Molecules

Abstract: Reactions of selenium and oxygen were performed using five different methods, and the products were trapped for matrix infrared spectroscopic study. Based on different chemistry, photolysis and annealing behavior, selenium and oxygen isotopic substitution, and DFT structure and frequency calculations, several new selenium oxides are characterized. In addition to SeO, SeO 2 , and SeO 3 , and the (Se 2 )(O 2 ) complex, the new molecules SeSeO, SeOO, Se 2 O 2 , and OSeOO are identified. Several isomers of Se 2 O … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

5
24
0

Year Published

1997
1997
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(29 citation statements)
references
References 35 publications
5
24
0
Order By: Relevance
“…But for the SeO À , the DZP++ B3LYP method predict the most accurate values (722.6 cm À1 ), which is close to the experimental data (730 ± 25 cm À1 ) [10]. The values (746.7 cm À1 ) provided by B3PW91 methods is also reasonable agreement with [16]. For the SeO 3 , Brabson and Andrews [16] is based on the discharge experiment and get a weak band at 997 cm À1 , which is similar to the data provided by Brisdon and Ogden [43].…”
Section: Dissociation Energies and Vibrational Frequenciessupporting
confidence: 79%
See 3 more Smart Citations
“…But for the SeO À , the DZP++ B3LYP method predict the most accurate values (722.6 cm À1 ), which is close to the experimental data (730 ± 25 cm À1 ) [10]. The values (746.7 cm À1 ) provided by B3PW91 methods is also reasonable agreement with [16]. For the SeO 3 , Brabson and Andrews [16] is based on the discharge experiment and get a weak band at 997 cm À1 , which is similar to the data provided by Brisdon and Ogden [43].…”
Section: Dissociation Energies and Vibrational Frequenciessupporting
confidence: 79%
“…Available experimental fundamentals are also included for comparison. Comparing with the limited experimental values for SeO, Brabson et al [16] had obtained frequency of 909.1 cm À1 by Matrix infrared spectra, which is just above the 906.2 cm À1 gas fundamental studied by Barrow et al [12]. At the same time, Brabson et al also used the DFT prediction frequency of 912.4 cm À1 .…”
Section: Dissociation Energies and Vibrational Frequenciesmentioning
confidence: 87%
See 2 more Smart Citations
“…[2] reported a similar, but not as accurate, geometry for the ground state. The calculated vibrational frequencies are slightly higher than the experimental values [25], and need to be scaled by a factor of about 0.95. Xu et al [2] listed ground state frequencies calculated by seven different functionals.…”
Section: Resultsmentioning
confidence: 65%