2009
DOI: 10.1021/jp905978z
|View full text |Cite
|
Sign up to set email alerts
|

Reaction of Protonated Tyrosine with Electronically Excited Singlet Molecular Oxygen (a1Δg): An Experimental and Trajectory Study

Abstract: Reaction of protonated tyrosine with the lowest electronically excited singlet state of molecular oxygen, (1)O(2) (a(1)Delta(g)), is reported over the center-of-mass collision energy (E(col)) range from 0.1 to 3.0 eV, using an electrospray-ionization, guided-ion-beam scattering instrument, in conjunction with ab initio electronic structure calculations and direct dynamics trajectory simulations. Only one product channel is observed, corresponding to generation of hydrogen peroxide via transfer of two hydrogen … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

6
87
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
8
1

Relationship

8
1

Authors

Journals

citations
Cited by 41 publications
(93 citation statements)
references
References 77 publications
6
87
0
Order By: Relevance
“…Mass spectra were acquired on a home-made guided-ionbeam tandem mass spectrometer described in detail previ- ously [8,9,[31][32][33][34]. The apparatus consists of an ESI [35,36] ion source, radio frequency (rf) hexapole ion guide [37], quadrupole mass filter, rf octopole ion guide surrounded by a scattering cell, second quadrupole mass filter, and a detector.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Mass spectra were acquired on a home-made guided-ionbeam tandem mass spectrometer described in detail previ- ously [8,9,[31][32][33][34]. The apparatus consists of an ESI [35,36] ion source, radio frequency (rf) hexapole ion guide [37], quadrupole mass filter, rf octopole ion guide surrounded by a scattering cell, second quadrupole mass filter, and a detector.…”
Section: Methodsmentioning
confidence: 99%
“…Sample solutions were sprayed into ambient atmosphere through an electrospray needle at a flow rate (0.03 or 0.04 ml h -1 ) optimized for each solution concentration. The electrospray needle was prepared in house [8,9,[31][32][33][34], and biased at −1,900 to −2,400 V relative to ground. Negatively charged droplets formed from ESI were fed into a heated desolvation capillary assembly.…”
Section: Methodsmentioning
confidence: 99%
“…The operation, calibration, and data analysis procedures for the mass spectrometer were described previously [57]. In brief, the apparatus consists of an ion source, radio frequency (rf) hexapole ion guide, quadrupole mass filter, rf octopole ion guide surrounded by a scattering cell, second quadrupole mass filter, and a pulse-counting detector.…”
Section: Esi Ms and Collision-induced Dissociation-tandem Ms Measuremmentioning
confidence: 99%
“…To avoid the complexities/interferences arising from solutionphase experiments and simplify the interpretation of the oxidation mechanisms of amino acids, we have looked at the reactions of 1 O 2 with protonated and deprotonated amino acids in the gas phase [7][8][9][10][11] using electrospray-ionization (ESI) 12,13 mass spectrometry and guided-ion-beam scattering methods. 14 One advantage of investigating biomolecules in the gas phase is that it allows one to observe single molecules separated from bulk solution environments.…”
Section: Introductionmentioning
confidence: 99%