Re‐establishing indwelling pleural catheter patency with alteplase after failure of streptokinase

Abstract: Indwelling pleural catheter (IPC) has revolutionized the management of malignant pleural effusion (MPE). IPC is relatively safe, although complications can occur. We report a 53‐year‐old woman with stage IVA lung adenocarcinoma and recurrent MPE. Two months post insertion, the IPC was blocked with residual effusion and presence of new loculations. Attempts to restore patency with six doses of intrapleural (IP) streptokinase failed. She was referred to our centre for further management. We used a single dose of… Show more