2021
DOI: 10.1016/j.measen.2021.100253
|View full text |Cite
|
Sign up to set email alerts
|

Rayleigh scattering for pressure assessment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
2

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 25 publications
0
4
0
Order By: Relevance
“…The UINT recently demonstrated an ability of assessing barometric pressure with an uncertainty of 10 ppm, improved by an order of magnitude as compared to previous achievements [23], [24], [25]. The UINT pressure standard has been also compared to a reference pressure standard, a barometer, in the 70-100 kPa range: the show a relative difference of ± 20 ppm for N2, fully covered by the related uncertainties.…”
Section: Wp2: Alternative Non Fabry-pérot Basedmentioning
confidence: 99%
See 1 more Smart Citation
“…The UINT recently demonstrated an ability of assessing barometric pressure with an uncertainty of 10 ppm, improved by an order of magnitude as compared to previous achievements [23], [24], [25]. The UINT pressure standard has been also compared to a reference pressure standard, a barometer, in the 70-100 kPa range: the show a relative difference of ± 20 ppm for N2, fully covered by the related uncertainties.…”
Section: Wp2: Alternative Non Fabry-pérot Basedmentioning
confidence: 99%
“…A custom software, written in Python, has been developed to analyse the acquired images from the camera detector, with the dual purpose of detecting and correcting effects caused by eventual spurious scattering centres and calculating the intensity of scattered light. The realized software and the design of the RAY system were presented in [23].…”
Section: Wp2: Alternative Non Fabry-pérot Basedmentioning
confidence: 99%
“…In the new SI, the uncertainty of the Boltzmann constant kB was eliminated, making advantageous to realise the pascal through number density measurements via optical methods, resulting in significant progress achieved in recent years at various metrological institutes and universities all around the world [1][2][3][4][5][6][7][8][9][10][11][12][13][14]. In this contest, a novel optical pressure standard, named UINT and alternative to Fabry-Perot cavity-based realizations, has recently developed [1].…”
Section: Introductionmentioning
confidence: 99%
“…A possible means to remedy such shortcomings is to employ quantum-based instrumentation that does not rely on any moving parts, and instead assesses pressure by utilizing knowledge of some fundamental properties of the gas [ 6 ]. Such instrumentation has over the last few decades experienced a significant development [ 7 , 8 , 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 , 17 , 18 ]. The interest in this type of techniques was further enhanced by the 2019 redefinition of the SI, in which the Boltzmann constant received an exact value [ 19 ].…”
Section: Introductionmentioning
confidence: 99%