2018
DOI: 10.17586/1606-4313-2018-17-2-78-84
|View full text |Cite
|
Sign up to set email alerts
|

Rationale and calculation of thermal comfort equivalent parameters

Abstract: Современные подходы к обоснованию комфортных параметров микроклимата жилых и производственных помещений в основном ориентированы на требования стандартов ISO 7730 и ASHRAE Standard 55. В статье описана методика расчета зависимостей требуемой температуры воздуха в функции от влажности, подвижности и радиационной разности температур при различных уровнях метаболизма и теплоизоляции одежды для помещений трех классов комфортности. Для каждого класса комфортности предварительно построены таблицы изокомфортных микро… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 4 publications
0
1
0
1
Order By: Relevance
“…At the same time, maintaining the required microclimate without overheating in winter and overcooling in summer helps to save energy [5][6][7]. Radiation temperature and local asymmetry of radiation temperature play an important role in the feeling of comfort in the rooms [8][9][10], often the assessment of the comfort of people staying indoors is given using the PMV indicator [11][12], in which the radiation temperature is also taken into account. In some cases, as, for example, with intermittent heating, the assessment of radiation temperature plays an important role, especially after a break in heating [13] or in unheated Orthodox churches [14,15].…”
Section: Introductionmentioning
confidence: 99%
“…At the same time, maintaining the required microclimate without overheating in winter and overcooling in summer helps to save energy [5][6][7]. Radiation temperature and local asymmetry of radiation temperature play an important role in the feeling of comfort in the rooms [8][9][10], often the assessment of the comfort of people staying indoors is given using the PMV indicator [11][12], in which the radiation temperature is also taken into account. In some cases, as, for example, with intermittent heating, the assessment of radiation temperature plays an important role, especially after a break in heating [13] or in unheated Orthodox churches [14,15].…”
Section: Introductionmentioning
confidence: 99%
“…Однако, система отопления в расчетном режиме работы будет находиться крайне редко, и под влиянием внутренних и внешних факторов [1] будет создавать переменный гидравлический режим в контуре системы [2]. При этом от точности регулирования и его возможности будет зависеть не только уровень теплового комфорта в обслуживаемом помещении [3], но и финансовые эксплуатационные затраты [4].…”
unclassified