2016
DOI: 10.1038/srep35440
|View full text |Cite
|
Sign up to set email alerts
|

Ratiometric ultrasensitive electrochemical immunosensor based on redox substrate and immunoprobe

Abstract: In this work, we presented a ratiometric electrochemical immunosensor based on redox substrate and immunoprobe. Carboxymethyl cellulose-Au-Pb2+ (CMC-Au-Pb2+) and carbon-Au-Cu2+ (C-Au-Cu2+) nanocomposites were firstly synthesized and implemented as redox substrate and immunoprobe with strong current signals at −0.45 V and 0.15 V, respectively. Human immunoglobulin G (IgG) was used as a model analyte to examine the analytical performance of the proposed method. The current signals of CMC-Au-Pb2+ (Isubstrate) and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 44 publications
0
10
0
Order By: Relevance
“…The redox substrate, which facilitates a strong current signal, has paved the way to enhance the analytical performance [53]. GO was used to increase the electrical conductivity on the surface and the stability of the 3-D porous structure, resulting in dual signal enhancement [54].…”
Section: Graphenementioning
confidence: 99%
“…The redox substrate, which facilitates a strong current signal, has paved the way to enhance the analytical performance [53]. GO was used to increase the electrical conductivity on the surface and the stability of the 3-D porous structure, resulting in dual signal enhancement [54].…”
Section: Graphenementioning
confidence: 99%
“…Metal ions possess good electrochemical redox activity, which makes them ideal materials as electrochemical signal substances [ 56 , 57 ]. With the advantages of easy accessibility and generated sharp electrochemical signal peaks, metal ions like silver ions, copper(II) ions, lead(II) ions usually serve as the excellent labels to indicate the content of multiple biomarkers [ 58 , 59 , 60 , 61 ]. Our group has come up with a method based on the chip-like GCE composed of three electrodes connected in a parallel for simultaneous detection [ 43 ].…”
Section: Electrochemical Signal Substances For Multiplexed Immunoassaymentioning
confidence: 99%
“…Metal NP sandwich-style sensors can improve selectivity combining the selectivity of antibodies, with the transducing properties of NPs. Tang and Ma constructed a sandwich assay for the detection of immunoglobulin G (IgG) using two functionalised AuNPs (Figure 36) [117]. Firstly, a GCE was functionalised with a carboxymethyl cellulose-Au-Pb 2+ nanocomposite, then labelled with the recognition antibody 1 (Ab1).…”
Section: Antibodiesmentioning
confidence: 99%