2021
DOI: 10.1007/s00604-021-04747-8
|View full text |Cite
|
Sign up to set email alerts
|

Ratiometric determination of Cr(VI) based on a dual-emission fluorescent nanoprobe using carbon quantum dots and a smartphone app

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(6 citation statements)
references
References 37 publications
0
6
0
Order By: Relevance
“…In summary, the FT-IR and XPS results of R-CDs are consistent. The existence of polar functional groups in R-CDs enables them to disperse well in aqueous solution, which also can promote their interaction with Cr(VI) [ 36 ].…”
Section: Resultsmentioning
confidence: 99%
“…In summary, the FT-IR and XPS results of R-CDs are consistent. The existence of polar functional groups in R-CDs enables them to disperse well in aqueous solution, which also can promote their interaction with Cr(VI) [ 36 ].…”
Section: Resultsmentioning
confidence: 99%
“…CQDs capable of easy functionalization, tunable PL, etc., portray diverse sensing applications. [ 274 ] The nonblinking PL capability enables tracking of single molecules and thus CQDs have been proved to be instrumental for the detection of heavy metal ions (Cr 6+/3+ , [ 90,275,276 ] Hg 2+ , [ 61,220,277–281 ] Fe 2+ , [ 23,113 ] Cu 2+ , [ 282–285 ] Ag +[ 286 ] ), anions (I − , [ 278 ] NO 2 − , [ 287 ] F − , [ 278 ] S 2 O 3 2− , [ 288 ] ClO −[ 289 ] ), small molecules (thrombin, [ 290 ] hyaluronidase, [ 291 ] glyphosate, [ 292 ] glucose, [ 56,127 ] H 2 O 2 , [ 49,56,285,293 ] dopamine, [ 70 ] tannic acid, [ 294 ] uric acid, [ 193 ] glycine, [ 295 ] ), temperature, [ 70 ] and pH [ 296,297 ] over the years. The capability of CQD to take up the dual roles of electron source and sink is the major reason for the fluorescent detections.…”
Section: Applicationsmentioning
confidence: 99%
“…Compared with these methods, the fluorescence analysis is considered preferable in DOX detection on account of its sensitivity, simplicity, and easy visualization . However, conventional fluorescence analysis primarily relies on a single fluorescent signal so it is susceptible to environmental and background interference during the sensing process . Dual-signal ratiometric fluorescent sensors can overcome this issue by providing an internal self-calibration system .…”
Section: Introductionmentioning
confidence: 99%