2018
DOI: 10.1109/tpwrd.2018.2850936
|View full text |Cite
|
Sign up to set email alerts
|

Rated Capacitance Determination of a New 1000 kV Equipotential Shielding Capacitor Voltage Transformer Under the Interference of Stray Capacitance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…In general, the total VDR of the CVT depends on the CVD, EMU, the temperature shift, power frequency variation, and proximity effects. Among them, it is believed that the CVD and EMU are the main factors [7]. e EMU is poured in an aluminum alloy box as a whole, so it is hardly affected by the external electromagnetic interference (EMI).…”
Section: Structure and Operation Principle Of The Cvtmentioning
confidence: 99%
See 2 more Smart Citations
“…In general, the total VDR of the CVT depends on the CVD, EMU, the temperature shift, power frequency variation, and proximity effects. Among them, it is believed that the CVD and EMU are the main factors [7]. e EMU is poured in an aluminum alloy box as a whole, so it is hardly affected by the external electromagnetic interference (EMI).…”
Section: Structure and Operation Principle Of The Cvtmentioning
confidence: 99%
“…us, it must be considered in the design of high-voltage devices. e stray capacitances of the CVT to ground and other charged parts play an important role in causing the VDR of the CVT [7]. Especially for the CVT applied in the ultra-high-voltage level, the effect of stray capacitance on its VDR is more serious [8].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…DCTV is an important primary equipment for the construction and operation of the DC electric power transmission, which provides accurate and reliable measurement information for the control and protection of the system. Its operation reliability and measurement accuracy are directly related to the safe and stable operation of the DC electric power transmission [1][2][3]. There are high-frequency coupling channels between the DC transmission and AC/DC systems, and the DC system contains a large amount of high-order harmonics.…”
Section: Introductionmentioning
confidence: 99%
“…9,14 However, the stray capacitances of compensation reactor and intermediate transformer are uncertain, and the parameter values of CVT are easily affected by temperature. 15 In order to calculate the values of stray capacitances, some works 16,17 pointed out that the relatively accurate method for calculating the values of stray capacitances is finite element analysis, but this method is complicated to operate.…”
Section: Introductionmentioning
confidence: 99%