2021
DOI: 10.1155/2021/8934998
|View full text |Cite
|
Sign up to set email alerts
|

Rapid Simultaneous Determination of 43 Pesticide Residues in Schizonepeta tenuifolia by Gas Chromatography Mass Spectrometry

Abstract: A simple, fast, and reliable method was established for simultaneous determination of 43 pesticides in Schizonepeta tenuifolia. The samples were prepared using solid-phase extraction (SPE) method. Pesticides were extracted from Schizonepeta tenuifolia using acetonitrile, cleaned with Pesticarb/NH2, and eluted by mixed solvents of acetonitrile and toluene (3 : 1, v/v). Selected pesticides were identified using DB-35MS capillary column and detected by gas chromatography mass spectrometry. Samples were quantified… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 24 publications
0
2
0
Order By: Relevance
“…At present, the SPE method can effectively separate pesticides and organic contaminants in a complex matrix. Zhou et al [ 18 ] developed a reliable protocol for quantitating 43 pesticides in Schizonepeta tenuifolia cleaned with Pesticarb/NH 2 cartridges. Li et al [ 19 ] screened for 439 pesticides in fruits and vegetables with Carb/NH 2 cartridges and obtained satisfactory results.…”
Section: Resultsmentioning
confidence: 99%
“…At present, the SPE method can effectively separate pesticides and organic contaminants in a complex matrix. Zhou et al [ 18 ] developed a reliable protocol for quantitating 43 pesticides in Schizonepeta tenuifolia cleaned with Pesticarb/NH 2 cartridges. Li et al [ 19 ] screened for 439 pesticides in fruits and vegetables with Carb/NH 2 cartridges and obtained satisfactory results.…”
Section: Resultsmentioning
confidence: 99%
“…The improvement of high-resolution mass spectrometry (HRMS) in resolution and obtaining appropriate selectivity by improving mass resolution provides new opportunities for residue analysis. Initially, GC and Q-TOF instruments were coupled through the atmospheric pressure chemical ionization (APCI) interface to achieve this goal [ 16 18 ], but recently, a special GC and electron ionization (EI) Orbitrap MS system was introduced. The system combines the peak capacity and chromatographic resolution of gas chromatography with the sub-ppm mass accuracy of the Orbitrap system to provide higher resolution (15,000, 30,000, 60,000, and 120,000 at half-maximum (FWHM) at m / z 200).…”
Section: Introductionmentioning
confidence: 99%