2003
DOI: 10.1016/s0969-8043(02)00293-2
|View full text |Cite
|
Sign up to set email alerts
|

Rapid screening of 2-[]-fluoro-2-deoxy-D-glucose infusions for volatile organic compound contaminants by solid phase microextraction with gas chromatography—selective ion monitoring mass spectrometry (SPME-GC-SIMMS)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 5 publications
0
3
0
Order By: Relevance
“…The loss of volatiles from sealed vials prior to analysis has been described recently in a study looking at the recovery of solvent residues from radio-pharmaceutical infusions. 8 In this instance the analyte losses of acetonitrile and ethanol were determined to be in the order of 75% to 98% over a period of 106 h.…”
Section: Rapid Screeningmentioning
confidence: 93%
“…The loss of volatiles from sealed vials prior to analysis has been described recently in a study looking at the recovery of solvent residues from radio-pharmaceutical infusions. 8 In this instance the analyte losses of acetonitrile and ethanol were determined to be in the order of 75% to 98% over a period of 106 h.…”
Section: Rapid Screeningmentioning
confidence: 93%
“…The instability of aqueous standards of low solubility VOCs has been noted previously 26,28 as have the precautions taken to account for the volatility, stability and low solubility of such compounds. Standards were used immediately after preparation, and cross-contamination checks were run by taking blank runs between every measurement.…”
Section: Preparation Of Reagents and Standardsmentioning
confidence: 95%
“…bumpy WO3 hemitube nanostructure assisted by O 2 plasma surface modification with functionalization of graphene-based material 41 , electrospun SnO 2 nanofibers sensitized with reduced graphene oxide nanosheets 42 , benzoyl-DL-arginine-naphthylamide (BANA) test 43 , High Performance Liquid Chromatography (HPLC) 44 and Solid-Phase Micro Extraction-Gas Chromatography/Mass Spectrometry (SPME-GC/MS 45 ). On the other hand, the device employed in this study might allow, for instance, fast data collection to rapidly achieve an early diagnosis of viral hepatitis B, which is also characterized by elevated dimethile sulfide levels 46 or to establish a state of systemic and/or respiratory disease (such as pneumonia, pulmonary emphysema and bronchitis) that are characterized by elevated hydrogen sulfide, methyl mercaptan and dimethyl sulfide levels 47 .…”
Section: Body Weight (Kg)mentioning
confidence: 99%