2014
DOI: 10.1002/2014jd021909
|View full text |Cite
|
Sign up to set email alerts
|

Rapid photochemical equilibration of isotope bond ordering in O2

Abstract: Abstract

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
36
1
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(39 citation statements)
references
References 50 publications
1
36
1
1
Order By: Relevance
“…The model that most closely matches our experimental findings is the PIMC model presented by Webb and Miller (2014). If we use our experimental products as a reference frame (following the reasoning behind the clumped isotope absolute reference frames for CO 2 , CH 4 , N 2 O and O 2 (Eiler and Schauble, 2004;Yeung et al, 2014;Stolper et al, 2014)), we can calculate the hydrogen isotope structure of CITP-1: δD central_SMOW = -208.3±6.6‰ and δD terminal_SMOW = -169.2±3.5‰ and = -47.1±8.9‰.…”
Section: Position-specific Hydrogen Isotope Fractionation At Thermodysupporting
confidence: 64%
See 1 more Smart Citation
“…The model that most closely matches our experimental findings is the PIMC model presented by Webb and Miller (2014). If we use our experimental products as a reference frame (following the reasoning behind the clumped isotope absolute reference frames for CO 2 , CH 4 , N 2 O and O 2 (Eiler and Schauble, 2004;Yeung et al, 2014;Stolper et al, 2014)), we can calculate the hydrogen isotope structure of CITP-1: δD central_SMOW = -208.3±6.6‰ and δD terminal_SMOW = -169.2±3.5‰ and = -47.1±8.9‰.…”
Section: Position-specific Hydrogen Isotope Fractionation At Thermodysupporting
confidence: 64%
“…We use this calibration to test the validity of prior published theoretical predictions. Comparison of data with models suggest the most sophisticated of these discrepant models (Webb and Miller, 2014) is most accurate; this conclusion implies that there is a combined experimental and theoretical foundation for an 'absolute reference frame' for positionspecific H isotope analysis of propane, following principles previously used for clumped isotope analysis of CO 2 , CH 4 and O 2 (Eiler and Schauble, 2004;Yeung et al, 2014;Stolper et al, 2014). …”
mentioning
confidence: 80%
“…In most other isotopic systems where the measurement of clumped isotopologues has been reported (CO 2 , carbonate, O 2 and methane), equilibrium exchange reactions comparable with those reviewed above form the basis for both calibrated geothermometers and an absolute reference frame for reporting clumped species . It is likely that the major natural processes that form N 2 O do not permit attainment of homogeneous equilibrium with respect to the proportions of isotopologues.…”
Section: Systematics Of Clumped and Position‐specific Isotope Effectsmentioning
confidence: 96%
“…In the stratosphere, O 3 photochemistry rearranges the isotopes in O 2 on timescales of months or less toward Δ 36 ≥ 2.3‰, corresponding to stratospheric temperatures below ~240 K [ Yeung et al ., , ]. In the troposphere, O 3 photochemistry rearranges isotopes in O 2 as well, but orders of magnitude more slowly and at warmer temperatures (Figure b).…”
Section: Introductionmentioning
confidence: 99%