2019
DOI: 10.1080/20961790.2019.1662648
|View full text |Cite
|
Sign up to set email alerts
|

Rapid on-site identification of hazardous organic compounds at fire scenes using person-portable gas chromatography-mass spectrometry (GC-MS)–part 2: water sampling and analysis

Abstract: Spikmans (2020) Rapid onsite identification of hazardous organic compounds at fire scenes using person-portable gas chromatography-mass spectrometry (GC-MS)-part 2: water sampling and analysis, Forensic

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
3
0
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 34 publications
0
3
0
1
Order By: Relevance
“…15,16 Jedni od prvih terenskih GC-MS uređaja bili su Viking SpectraTrak™ 672 i Bruker EM 640S koji su bili relativno velikih dimenzija i vrlo teški, a okolišni uvjeti znatno su utjecali na njihov rad. 17 Današnji prijenosni GC-MS uređaji (slika 1) malih su dimenzija i mase 10 -20 kg te omogućuju detekciju i identifikaciju koja za hlapljive i djelomično hlapljive organske spojeve traje do 10 min. Kod slabo hlapljivih spojeva prije analize se mora provesti prilično zahtjevna priprema uzorka koja je dugotrajna, složena i rizična te se obavlja u najvišem stupnju zaštitne opreme.…”
Section: Prijenosna Gc-ms Detekcijaunclassified
“…15,16 Jedni od prvih terenskih GC-MS uređaja bili su Viking SpectraTrak™ 672 i Bruker EM 640S koji su bili relativno velikih dimenzija i vrlo teški, a okolišni uvjeti znatno su utjecali na njihov rad. 17 Današnji prijenosni GC-MS uređaji (slika 1) malih su dimenzija i mase 10 -20 kg te omogućuju detekciju i identifikaciju koja za hlapljive i djelomično hlapljive organske spojeve traje do 10 min. Kod slabo hlapljivih spojeva prije analize se mora provesti prilično zahtjevna priprema uzorka koja je dugotrajna, složena i rizična te se obavlja u najvišem stupnju zaštitne opreme.…”
Section: Prijenosna Gc-ms Detekcijaunclassified
“…The in-field results do not need to be confirmatory and do not have to withstand scrutiny in court (Lam et al 2019b ; Spikmans 2019 ). The in-field results need to provide preliminary information on the pollutant(s) present in a timely manner to allow the field officer to manage the site to protect the environment (Galuszka et al 2015 ; Lam et al 2018 ; Spikmans 2019 ).…”
Section: Introductionmentioning
confidence: 99%
“…Given these requirements, miniaturised field-portable equipment is highly suited for the task (Guidotti et al 2020 ; Lam et al 2019b ; Valcárcel and Cárdenas 2005 ). Fit-for-purpose results can be obtained despite potential sacrifices in performance due to miniaturisation, shorter analysis times, and whilst being used in uncontrolled environmental conditions (Bartley et al 2007 ; Galuszka et al 2015 ; Turl and Wood 2008 ).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation