2019
DOI: 10.1007/s10967-019-06438-4
|View full text |Cite
|
Sign up to set email alerts
|

Rapid measurements of 235U fission product isotope ratios using an online, high-pressure ion chromatography inductively coupled plasma mass spectrometry protocol with comparison to isotopic depletion models

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 48 publications
0
9
0
Order By: Relevance
“…Signal smoothing enabled the fitted peak areas between isotope peaks from the same element to be compared, yielding isotopic ratios in atom percent. The peak fitting and smoothing settings applied to determine peak area, found within the "Peak Detection" settings of the Qtegra software, are as detailed previously [27,28,33]. Where slight peak overlap occurred for Yb and Lu the isobaric peaks were statistically deconvoluted using the "multiple peak fitting" function of the OriginLab ® OriginPro ® 2018 graphing software (OriginLab Corporation, Wellesley Hills, MA, USA).…”
Section: Instrumentationmentioning
confidence: 99%
See 2 more Smart Citations
“…Signal smoothing enabled the fitted peak areas between isotope peaks from the same element to be compared, yielding isotopic ratios in atom percent. The peak fitting and smoothing settings applied to determine peak area, found within the "Peak Detection" settings of the Qtegra software, are as detailed previously [27,28,33]. Where slight peak overlap occurred for Yb and Lu the isobaric peaks were statistically deconvoluted using the "multiple peak fitting" function of the OriginLab ® OriginPro ® 2018 graphing software (OriginLab Corporation, Wellesley Hills, MA, USA).…”
Section: Instrumentationmentioning
confidence: 99%
“…The offline separation protocol was adapted from Roach et al [28]. Each injection had ~30 min separation (1 mL min −1 ) which included a 5 min washing step (5% oxalic acid and 95% water) at the end of the separation.…”
Section: Hpic Separationmentioning
confidence: 99%
See 1 more Smart Citation
“…The atomic percent ratios will be converted to mass percent before reporting. The chromatographic peak fitting and smoothing settings applied to determine peak areas, found within the "Peak Detection" settings of Qtegra, are as detailed previously [3][4][5][6][7].…”
Section: Software and Data Processingmentioning
confidence: 99%
“…The coupled instruments will be housed within a radiological fume hood, facilitating the analyses of radioactive samples. The method development, isotopic detection limits, system stability, elution profiles, data analysis, method uncertainties, and various uranium-based applications have been reported previously [6][7][8][9][10][11]. RAPID will be used to directly measure the isotopic composition of the isolated elements in real time.…”
Section: Rapid Separation Protocolmentioning
confidence: 99%