Rapid Intradermal Delivery of Liquid Formulations Using a Hollow Microstructured Array

Abstract: PurposeThe purpose of this work is to demonstrate rapid intradermal delivery of up to 1.5 mL of formulation using a hollow microneedle delivery device designed for self-application.Methods3M’s hollow Microstructured Transdermal System (hMTS) was applied to domestic swine to demonstrate delivery of a variety of formulations including small molecule salts and proteins. Blood samples were collected after delivery and analyzed via HPLC or ELISA to provide a PK profile for the delivered drug. Site evaluations were … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
58
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 102 publications
(61 citation statements)
references
References 14 publications
0
58
0
Order By: Relevance
“…These volumes were also much higher as those reported for single HMN in human skin (20 μL/HMN) (23) or HMN arrays in mice skin (0.22 μL/HMN) (26). Additionally, achieved volumes were comparable to HMN arrays in porcine skin (83.33 μL/ HMN) (27). Furthermore, a single hollow needle design reduces the risk of volume loss (dose loss) compared to HMN arrays, as in arrays all needles need to be penetrated and unclogged to ensure an accurate injection and prevent leakage (28,29).…”
Section: Discussionmentioning
confidence: 51%
“…These volumes were also much higher as those reported for single HMN in human skin (20 μL/HMN) (23) or HMN arrays in mice skin (0.22 μL/HMN) (26). Additionally, achieved volumes were comparable to HMN arrays in porcine skin (83.33 μL/ HMN) (27). Furthermore, a single hollow needle design reduces the risk of volume loss (dose loss) compared to HMN arrays, as in arrays all needles need to be penetrated and unclogged to ensure an accurate injection and prevent leakage (28,29).…”
Section: Discussionmentioning
confidence: 51%
“…Opioid analgesics are the agents of choice to treat the severe pain associated with cancer. Since, the drug has to be administered frequently for a long period, the drug delivery system should be such that gives the maximum bioavailability of the drug, so that the patient gets the highest therapeutic benefit without getting exposed to high doses 8 .…”
Section: Acute and Chronic Painmentioning
confidence: 99%
“…These can be solid, hollow, fabricated from silicon material and plastic materials such as polycarbonates. Microneedles have hundreds of needles per array, ranging in size from 100 microns to 2 mm 8,92 .…”
Section: Microneedlementioning
confidence: 99%
“…[25] A hilltop chamber was attached to the application site. After a 10-min staining period, the chamber was removed followed by washing with distilled water and observed for penetration.…”
Section: In-vivo Testmentioning
confidence: 99%