2018
DOI: 10.3390/en11061534
|View full text |Cite
|
Sign up to set email alerts
|

Rapid Fault Diagnosis of a Back-to-Back MMC-HVDC Transmission System under AC Line Fault

Abstract: Abstract:The integration of a modular multilevel converter-based high-voltage direct current (MMC-HVDC) transmission system in power networks has led to a high requirement for the rapidity of fault recognition. This study focused on the rapid fault diagnosis of an alternating current (AC) line fault in a back-to-back (BTB) MMC-HVDC system via fault detection and classification. Discrete wavelet transform and modulus maxima were applied to extract the fault features. Phase-mode transformation and normalization … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2
1
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 14 publications
0
4
0
Order By: Relevance
“…To further highlight the advantages of the proposed method in this aspect of fault classification, Table IV provides comparative data of several methods. From them, the method proposed in [14] shows that the threshold criteria for single-, two-, and three-phase-to-ground faults are greater than 0.05, less than 0.05, and equal to 0, respectively. Compared with the method proposed in this paper, the threshold criterion of the method in [14] is too small, and it may not be able to accurately determine the fault type.…”
Section: Comparison With Other Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…To further highlight the advantages of the proposed method in this aspect of fault classification, Table IV provides comparative data of several methods. From them, the method proposed in [14] shows that the threshold criteria for single-, two-, and three-phase-to-ground faults are greater than 0.05, less than 0.05, and equal to 0, respectively. Compared with the method proposed in this paper, the threshold criterion of the method in [14] is too small, and it may not be able to accurately determine the fault type.…”
Section: Comparison With Other Methodsmentioning
confidence: 99%
“…From them, the method proposed in [14] shows that the threshold criteria for single-, two-, and three-phase-to-ground faults are greater than 0.05, less than 0.05, and equal to 0, respectively. Compared with the method proposed in this paper, the threshold criterion of the method in [14] is too small, and it may not be able to accurately determine the fault type. Meanwhile, this method has smaller differences in the criteria for the same type of fault.…”
Section: Comparison With Other Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For AC side faults, in, 47 the authors proposed a method to detect and classify faults on the AC side of MMC. The feature extraction phenomenon uses discrete wavelets transform (DWT) and modulus maxima (MM).…”
Section: Fault Diagnosis and Control Techniques For MMCmentioning
confidence: 99%