2003
DOI: 10.1016/s0720-048x(03)00077-9
|View full text |Cite
|
Sign up to set email alerts
|

Rapid estimation of the vertebral body volume: a combination of the Cavalieri principle and computed tomography images

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
55
0
2

Year Published

2004
2004
2015
2015

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 68 publications
(58 citation statements)
references
References 32 publications
1
55
0
2
Order By: Relevance
“…The values obtained in this way are reliable and reproducible. Moreover, the stereological approach could be easily applied without altering routine procedures and the obtained data show little inter-observer variation both at microscopic and macroscopic levels (24,29). Finally, the results of this research will provide an insight for investigation and comparison of hypertrophy, atrophy, and tumor formation in the kidneys.…”
Section: Discussionmentioning
confidence: 75%
See 1 more Smart Citation
“…The values obtained in this way are reliable and reproducible. Moreover, the stereological approach could be easily applied without altering routine procedures and the obtained data show little inter-observer variation both at microscopic and macroscopic levels (24,29). Finally, the results of this research will provide an insight for investigation and comparison of hypertrophy, atrophy, and tumor formation in the kidneys.…”
Section: Discussionmentioning
confidence: 75%
“…The volume of biological structures can be obtained by the Cavalieri principle of stereological volume estimation as described in the previous studies (3,9,24,28). This approach allows the evaluation of the volumes of macroscopic and microscopic tissues (25,27) on the basis of physical sections.…”
Section: Introductionmentioning
confidence: 99%
“…Previous studies showed that the obtained volumes using the Cavalieri principle on sectional radiological images showed little inter-rater variation Odaci et al, 2003;Akbaş et al, 2004). However, these studies are not conducted on the brain or its components.…”
Section: Discussionmentioning
confidence: 98%
“…20) In the Cavalieri principle, a researcher obtains the coefficient of error (CE) to evaluate the reliability of the point density of the grids and sectioning intervals. The CE, or relative standard error, represents the precision of the volume estimate obtained using the Cavalieri principle.…”
Section: Methodsmentioning
confidence: 99%
“…The mean of the two repeated number points counted for any section was used to estimate the section cut surface area for the horizontal scan plan and the volume of the tumor was then estimated using the formula previously described. 17,[20][21][22] Two investigators estimated the volumes of the tumor area on each image of the horizontal plane using the same sets of printed sections of the chest to check the accuracy and the validity of the estimates.…”
Section: Methodsmentioning