Rapid determination of vitamin C by NIR, MIR and FT-Raman techniques

Abstract: Rapid spectroscopic determination of vitamin C in food and pharmaceutical products using infrared and Raman techniques was proposed. In this study, near-infrared (NIR), Fourier transform near-infrared (FT-NIR), Fourier transform infrared-attenuated total reflectance (FTIR-ATR), diffuse reflectance (DRIFTS), Fourier transform infrared-photoacoustic (FTIR-PAS) and FT-Raman spectroscopy were used in conjunction with partial least squares (PLS) regression to quantify vitamin C in powdered mixtures and solutions. R… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
50
0
1

Year Published

2004
2004
2017
2017

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 105 publications
(55 citation statements)
references
References 17 publications
(16 reference statements)
1
50
0
1
Order By: Relevance
“…68 In this study, near-IR (NIR), Fourier transform (FT) NIR, FT IR-attenuated total reflectance (FTIR-ATR), diffuse reflectance (DRIFTS), FT IR-photoacoustic (FTIR-PAS) and FT-Raman spectroscopy were used in conjunction with partial least-squares (PLS) regression to quantify vitamin C in powders, mixtures and solutions. The results indicated that the methods adopted have high prediction correlation with an overall prediction error of 0.2-3.0%.…”
Section: Vitamin C (Ascorbic Acid)mentioning
confidence: 99%
“…68 In this study, near-IR (NIR), Fourier transform (FT) NIR, FT IR-attenuated total reflectance (FTIR-ATR), diffuse reflectance (DRIFTS), FT IR-photoacoustic (FTIR-PAS) and FT-Raman spectroscopy were used in conjunction with partial least-squares (PLS) regression to quantify vitamin C in powders, mixtures and solutions. The results indicated that the methods adopted have high prediction correlation with an overall prediction error of 0.2-3.0%.…”
Section: Vitamin C (Ascorbic Acid)mentioning
confidence: 99%
“…Instrumentation analytical methods that are neither destructive nor produce residues have been increasingly investigated for the identification and quantification of active ingredients, using infrared spectroscopy (Blanco et al, 2000a;Blanco et al, 2000b;Blanco et al, 2001;Braga, Poppi, 2004;Pasquini, 2003;Sun, Xiang, An, 2004;Yang, Irudayaraj, 2002).…”
Section: Introductionmentioning
confidence: 99%
“…The interface between chemometric tools and the data obtained by infrared methods offers new possibilities for the quantification and qualification of pharmaceutical drugs (Blanco et al, 2000a;Blanco et al, 2000b;Blanco et al, 2001;Pasquini, 2003;Yang, Irudayaraj, 2002;Ferrão, Davanzo, 2005). On top of that, because it is a simple, easily obtained and non-destructive method, its procedures are appropriate for pharmaceutical formulations.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Associada ao crescente desenvolvimento do método de refletância difusa, este tipo de análise garante a caracterização de fármacos com extrema rapidez. A identificação destas substâncias pode ser alcançada tanto quantitativamente como qualitativamente através da espectroscopia por refletância difusa no infravermelho com transformada de Fourier (Diffuse Reflectance Infrared Fourier Transform Spectroscopy -DRIFTS) (Yang, Irudayaraj, 2002), aliada a ferramentas quimiométricas de análise multivariada (Neumann et al, 2004;Parisotto et al, 2005).…”
Section: Introductionunclassified