1997
DOI: 10.1039/a700956i
|View full text |Cite
|
Sign up to set email alerts
|

Rapid Determination of Inorganic Mercury and Methylmercury in Biological Reference Materials by Hydride Generation, Cryofocusing, Atomic Absorption Spectrometry After Open Focused Microwave-assisted Alkaline Digestion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
110
0

Year Published

1998
1998
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 183 publications
(114 citation statements)
references
References 44 publications
4
110
0
Order By: Relevance
“…This material was then extracted using an adaptation of a published method, 8 briefly described here; tetramethylammonium hydroxide (6 mL) was added to the spiked material (1.0 g) which was then heated in a microwave sample preparation system (Multiwave, Perkin Elmer, Norwalk. USA) to a maximum temperature of 80°C for 20 mins., using 120 W of power.…”
Section: Sample Preparationmentioning
confidence: 99%
“…This material was then extracted using an adaptation of a published method, 8 briefly described here; tetramethylammonium hydroxide (6 mL) was added to the spiked material (1.0 g) which was then heated in a microwave sample preparation system (Multiwave, Perkin Elmer, Norwalk. USA) to a maximum temperature of 80°C for 20 mins., using 120 W of power.…”
Section: Sample Preparationmentioning
confidence: 99%
“…Solvents such as TMAH [21], KOH/CH 3 OH [22] or HCl [23] or Cu 2 þ in acid circumstance [24] have often been used as the extractants. However, there is still no comprehensive evaluation of preparation for mercury speciation in petroleum.…”
Section: Introductionmentioning
confidence: 99%
“…The most common chromatographic detectors are universal or selective but, unfortunately, lack the required specificity. For mercury speciation, the most common techniques used include cold vapour (CV) atomic absorption spectrometry (AAS), [30][31][32][33][34][35] cold-vapor atomic fluorescence spectrometry (CVAFS), [36][37][38][39] inductively coupled plasma mass spectrometry (ICP-MS), 4,[40][41][42] microwave induced plasma atomic emission spectrometry (MIP-AES) 40,43,44 and furnace atomization plasma emission spectrometry (FAPES). [45][46][47] FAPES is an atomic emission technique which capacitively links a conventional graphite furnace with a coaxial electrode to which radiofrequency power is applied, thereby generating an atmospheric He plasma within the volume of the graphite tube.…”
Section: Introductionmentioning
confidence: 99%